Dynamic multi-coil tailored excitation for transmit B1 correction at 7 Tesla.

S Umesh Rudrapatna1, Christoph Juchem1, Terence W Nixon1, Robin A de Graaf1.   

Abstract

PURPOSE: Tailored excitation (TEx) based on interspersing multiple radio frequency pulses with linear gradient and higher-order shim pulses can be used to obtain uniform flip angle in the presence of large radio frequency transmission (B 1+) inhomogeneity. Here, an implementation of dynamic, multislice tailored excitation using the recently developed multi-coil nonlinear shim hardware (MC-DTEx) is reported.
METHODS: MC-DTEx was developed and tested both in a phantom and in vivo at 7 T, and its efficacy was quantitatively assessed. Predicted outcomes of MC-DTEx and DTEx based on spherical harmonic shims (SH-DTEx) were also compared.
RESULTS: For a planned 30 ° flip angle, in a phantom, the standard deviation in excitation improved from 28% (regular excitation) to 12% with MC-DTEx. The SD in in vivo excitation improved from 22 to 12%. The improvements achieved with experimental MC-DTEx closely matched the theoretical predictions. Simulations further showed that MC-DTEx outperforms SH-DTEx for both scenarios.
CONCLUSION: Successful implementation of multislice MC-DTEx is presented and is shown to be capable of homogenizing excitation over more than twofold B 1+ variations. Its benefits over SH-DTEx are also demonstrated. A distinct advantage of MC hardware over SH shim hardware is the absence of significant eddy current effects, which allows for a straightforward, multislice implementation of MC-DTEx. Magn Reson Med 76:83-93, 2016.
© 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  B1 shimming; DYNAMITE; dynamic shimming; multi-coil; radio frequency; wavelength effects

Mesh:

Year:  2015        PMID: 26223503     DOI: 10.1002/mrm.25856

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  3 in total

Review 1.  Studying neuroanatomy using MRI.

Authors:  Jason P Lerch; André J W van der Kouwe; Armin Raznahan; Tomáš Paus; Heidi Johansen-Berg; Karla L Miller; Stephen M Smith; Bruce Fischl; Stamatios N Sotiropoulos
Journal:  Nat Neurosci       Date:  2017-02-23       Impact factor: 24.884

2.  The public multi-coil information (PUMCIN) policy.

Authors:  Christoph Juchem; Robin A de Graaf
Journal:  Magn Reson Med       Date:  2016-12-01       Impact factor: 4.668

3.  Ultrafast B1 mapping with RF-prepared 3D FLASH acquisition: Correcting the bias due to T1 -induced k-space filtering effect.

Authors:  Dan Zhu; Michael Schär; Qin Qin
Journal:  Magn Reson Med       Date:  2022-04-05       Impact factor: 3.737

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.