Literature DB >> 26223463

HILIC-MS Determination of Genotoxic Impurity of 2-Chloro-N-(2-Chloroethyl)Ethanamine in the Vortioxetine Manufacturing Process.

Michal Douša1, Robert Klvaňa2, Jan Doubský2, Jan Srbek2, Jindřich Richter2, Marek Exner3, Petr Gibala2.   

Abstract

In the last decade, pharmaceutical regulatory agencies are focused on monitoring and evaluation of trace-level genotoxic impurities (GTIs) in drug substances, which requires manufacturers to deliver innovative approaches for their analysis and control. GTIs in the low p.p.m. level rising from the process of drug production have to be positively identified and quantified. Therefore, sensitive and selective analytical methods are necessary for required quantification level of these GTIs. Unfortunately, general guidance on how to develop strategy of the analysis and control of GTIs is currently missing in the pharmaceutical industry. Therefore, practical example of the analytical control of 2-chloro-N-(2-chloroethyl)ethanamine GTI in the vortioxetine (VOR) manufacturing process was demonstrated in this work. QDa mass detection with electrospray ionization in selected-ion recording mode was utilized for quantitation of GTIs. The method of hydrophilic interaction liquid chromatography coupled with mass spectrometry detection (HILIC-MS) was validated as per International Conference on Harmonization guidelines and was able to quantitate GTIs at 75 p.p.m. with respect to VOR. The HILIC-MS method was achieved using a Primesep B column (150 × 4.6 mm, 5.0 µm; Sielc, USA) using mobile phase consisting of 10 mM ammonium formate buffer pH 3.0 and acetonitrile (5 : 95, v/v) at 0.8 mL/min flow rate. The QDa mass detector was operated in the positive ion mode. Quadrupole mass analyzer was employed in selected-ion monitoring mode using target ion at m/z 142 as [M+H](+).
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26223463     DOI: 10.1093/chromsci/bmv107

Source DB:  PubMed          Journal:  J Chromatogr Sci        ISSN: 0021-9665            Impact factor:   1.618


  2 in total

1.  Rapid, direct, and sensitive determination of aziridine and 2-chloroethylamine by hydrophilic interaction liquid chromatography-mass spectrometry.

Authors:  Jonathan G Shackman
Journal:  MethodsX       Date:  2019-09-18

2.  Development of the Validated Stability-Indicating Method for the Determination of Vortioxetine in Bulk and Pharmaceutical Formulation by HPLC-DAD, Stress Degradation Kinetics Studies and Detection of Degradation Products by LC-ESI-QTOF-MS.

Authors:  Karol Wróblewski; Małgorzata Szultka-Młyńska; Daria Janiszewska; Anna Petruczynik; Bogusław Buszewski
Journal:  Molecules       Date:  2022-03-14       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.