Literature DB >> 26216052

Quantitative myocardial perfusion PET parametric imaging at the voxel-level.

Hassan Mohy-Ud-Din1, Martin A Lodge, Arman Rahmim.   

Abstract

Quantitative myocardial perfusion (MP) PET has the potential to enhance detection of early stages of atherosclerosis or microvascular dysfunction, characterization of flow-limiting effects of coronary artery disease (CAD), and identification of balanced reduction of flow due to multivessel stenosis. We aim to enable quantitative MP-PET at the individual voxel level, which has the potential to allow enhanced visualization and quantification of myocardial blood flow (MBF) and flow reserve (MFR) as computed from uptake parametric images. This framework is especially challenging for the (82)Rb radiotracer. The short half-life enables fast serial imaging and high patient throughput; yet, the acquired dynamic PET images suffer from high noise-levels introducing large variability in uptake parametric images and, therefore, in the estimates of MBF and MFR. Robust estimation requires substantial post-smoothing of noisy data, degrading valuable functional information of physiological and pathological importance. We present a feasible and robust approach to generate parametric images at the voxel-level that substantially reduces noise without significant loss of spatial resolution. The proposed methodology, denoted physiological clustering, makes use of the functional similarity of voxels to penalize deviation of voxel kinetics from physiological partners. The results were validated using extensive simulations (with transmural and non-transmural perfusion defects) and clinical studies. Compared to post-smoothing, physiological clustering depicted enhanced quantitative noise versus bias performance as well as superior recovery of perfusion defects (as quantified by CNR) with minimal increase in bias. Overall, parametric images obtained from the proposed methodology were robust in the presence of high-noise levels as manifested in the voxel time-activity-curves.

Entities:  

Mesh:

Year:  2015        PMID: 26216052     DOI: 10.1088/0031-9155/60/15/6013

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  On the assessment of spatial resolution of PET systems with iterative image reconstruction.

Authors:  Kuang Gong; Simon R Cherry; Jinyi Qi
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

2.  3.0 T magnetic resonance myocardial perfusion imaging for semi-quantitative evaluation of coronary microvascular dysfunction in hypertrophic cardiomyopathy.

Authors:  Liang Yin; Hai-Yan Xu; Sui-Sheng Zheng; Ying Zhu; Jiang-Xi Xiao; Wei Zhou; Si-Si Yu; Liang-Geng Gong
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-13       Impact factor: 2.357

3.  Joint solution for PET image segmentation, denoising, and partial volume correction.

Authors:  Ziyue Xu; Mingchen Gao; Georgios Z Papadakis; Brian Luna; Sanjay Jain; Daniel J Mollura; Ulas Bagci
Journal:  Med Image Anal       Date:  2018-03-28       Impact factor: 8.545

Review 4.  Dynamic whole-body PET imaging: principles, potentials and applications.

Authors:  Arman Rahmim; Martin A Lodge; Nicolas A Karakatsanis; Vladimir Y Panin; Yun Zhou; Alan McMillan; Steve Cho; Habib Zaidi; Michael E Casey; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-09-29       Impact factor: 9.236

5.  Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels.

Authors:  Mary Germino; Jean-Dominque Gallezot; Jianhua Yan; Richard E Carson
Journal:  Phys Med Biol       Date:  2017-05-15       Impact factor: 3.609

6.  Comparison of quantitative myocardial perfusion imaging CT to fluorescent microsphere-based flow from high-resolution cryo-images.

Authors:  Brendan L Eck; Rachid Fahmi; Jacob Levi; Anas Fares; Hao Wu; Yuemeng Li; Mani Vembar; Amar Dhanantwari; Hiram G Bezerra; David L Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

7.  Striatal Dopamine Release in Response to Morphine: A [11C]Raclopride Positron Emission Tomography Study in Healthy Men.

Authors:  Primavera A Spagnolo; Alane Kimes; Melanie L Schwandt; Ehsan Shokri-Kojori; Shantalaxmi Thada; Karran A Phillips; Nancy Diazgranados; Kenzie L Preston; Peter Herscovitch; Dardo Tomasi; Vijay A Ramchandani; Markus Heilig
Journal:  Biol Psychiatry       Date:  2019-03-15       Impact factor: 13.382

8.  Non-invasive measures of coronary microcirculation: Taking the long road to the clinic.

Authors:  Kieran S Chung; Patricia K Nguyen
Journal:  J Nucl Cardiol       Date:  2017-07-18       Impact factor: 5.952

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.