| Literature DB >> 26213448 |
Lee A Greenawald1, Jay L Snyder2, Nicole L Fry3, Michael J Sailor3, Gerry R Boss4, Harry O Finklea5, Suzanne Bell5.
Abstract
We describe an inexpensive paper-based sensor for rapid detection of low concentrations (ppm) of hydrogen cyanide gas. A piece of filter paper pre-spotted with a dilute monocyanocobinamide [CN(H2O)Cbi] solution was placed on the end of a bifurcated optical fiber and the reflectance spectrum of the CN(H2O)Cbi was monitored during exposure to 1.0-10.0 ppm hydrogen cyanide gas. Formation of dicyanocobinamide yielded a peak at 583 nm with a simultaneous decrease in reflectance from 450-500 nm. Spectral changes were monitored as a function of time at several relative humidity values: 25, 50, and 85% relative humidity. With either cellulose or glass fiber papers, spectral changes occurred within 10 s of exposure to 5.0 ppm hydrogen cyanide gas (NIOSH recommended short-term exposure limit). We conclude that this sensor could provide a real-time end-of-service-life alert to a respirator user.Entities:
Keywords: Cobinamide; Diffuse reflectance; End-of-service-life indicator; Hydrogen cyanide; Optical sensor; Paper sensor
Year: 2015 PMID: 26213448 PMCID: PMC4511729 DOI: 10.1016/j.snb.2015.06.085
Source DB: PubMed Journal: Sens Actuators B Chem ISSN: 0925-4005 Impact factor: 7.460