Literature DB >> 26211634

Investigation of PM2.5 and carbon dioxide levels in urban homes.

Mahmoud M M Abdel-Salam1.   

Abstract

PM2.5 (particulate matter with an aerodynamic diameter <2.5 μm) samples were collected in the indoor environments of 15 urban homes and their adjacent outdoor environments in Alexandria, Egypt, during the spring time. Indoor and outdoor carbon dioxide (CO₂) levels were also measured concurrently. The results showed that indoor and outdoor PM2.5 concentrations in the 15 sites, with daily averages of 45.5 ± 11.1 and 47.3 ± 12.9 µg/m³, respectively, were significantly higher than the ambient 24-hr PM2.5 standard of 35 µg/m³ recommended by the U.S. Environmental Protection Agency (EPA). The indoor PM2.5 and CO₂levels were correlated with the corresponding outdoor levels, demonstrating that outdoor convection and infiltration could lead to direct transportation indoors. Ventilation rates were also measured in the selected residences and ranged from 1.6 to 4.5 hr⁻¹ with median value of 3.3 hr⁻¹. The indoor/outdoor (I/O) ratios of the monitored homes varied from 0.73 to 1.65 with average value of 0.99 ± 0.26 for PM2.5, whereas those for CO₂ranged from 1.13 to 1.66 with average value of 1.41 ± 0.15. Indoor sources and personal activities, including smoking and cooking, were found to significantly influence indoor levels.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26211634     DOI: 10.1080/10962247.2015.1040138

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  4 in total

1.  Carbon dioxide effects on daytime sleepiness and EEG signal: A combinational approach using classical frequentist and Bayesian analyses.

Authors:  Rui Nian Jin; Hitoshi Inada; János Négyesi; Daisuke Ito; Ryoichi Nagatomi
Journal:  Indoor Air       Date:  2022-06       Impact factor: 6.554

Review 2.  A systematic literature review on indoor PM2.5 concentrations and personal exposure in urban residential buildings.

Authors:  Yu Liu; Hongqiang Ma; Na Zhang; Qinghua Li
Journal:  Heliyon       Date:  2022-08-10

3.  Controlling Indoor Air Pollution from Moxibustion.

Authors:  Chung-Yen Lu; Sy-Yuan Kang; Shu-Hui Liu; Cheng-Wei Mai; Chao-Heng Tseng
Journal:  Int J Environ Res Public Health       Date:  2016-06-20       Impact factor: 3.390

4.  Impact of Outdoor Air Pollution on Indoor Air Quality in Low-Income Homes during Wildfire Seasons.

Authors:  Prateek M Shrestha; Jamie L Humphrey; Elizabeth J Carlton; John L Adgate; Kelsey E Barton; Elisabeth D Root; Shelly L Miller
Journal:  Int J Environ Res Public Health       Date:  2019-09-21       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.