Literature DB >> 26209484

Pulmonary Artery Sealing Using the HARMONIC ACE+ Shears for Video-Assisted Thoracoscopic Surgery Lobectomy.

Moishe Liberman1, Mohamed Khereba2, Basil Nasir2, Eric Goudie2, Alain Danino3, Jean-Philippe Giot3, Nathanael Nizard3, Rachid Hadjeres4, Vicky Thiffault2, Nicolas Farrenq2, Pasquale Ferraro2.   

Abstract

BACKGROUND: The standard technique for pulmonary arterial (PA) branch sealing in video-assisted thoracoscopic surgery lobectomy consists of vascular endostaplers. We evaluated the immediate efficacy of an ultrasonic energy vessel-sealing device for sealing PA branches and compared it with the gold standard (endostapler) in an ex vivo model.
METHODS: This was a prospective cohort study. Immediately after anatomical lung resection, PA vessel sealing was achieved using the HARMONIC ACE+ Shears (ACE; Ethicon, Cincinnati, OH) sealing device or a vascular endostapler (VES) in a 3:1 ratio based on vessel diameter. The vessel was slowly pressurized, and the bursting pressure was recorded.
RESULTS: A total of 137 PA branches were sealed in specimens from 43 patients, of which 90 vessels were sealed with ACE and 47 were sealed with VES. The mean PA branch diameter was 6.0 mm (range, 1.7 mm to 24.0 mm; standard deviation, 3.1 mm Hg). The mean bursting pressure was 333.0 mm Hg (range, 84.0 mm Hg to 1415.1 mm Hg; standard deviation, 231.4 mm Hg) in the ACE group and 114.2 mm Hg (range, 0 mm Hg to 840.0 mm Hg; standard deviation, 124.7) in the VES group (p < 0.001). There were no complete sealing failures in the ACE group. Electron microscopy of ACE-sealed PA vessels demonstrated adventitial sealing with partial preservation of the collagen bundles and media with a sealed matrix of melted collagen.
CONCLUSIONS: PA branches sealed using the HARMONIC ACE+ in a simulated ex vivo model were able to sustain high intraluminal pressures. ACE-sealed vessels burst at mean bursting pressures equal to or greater than the VES-stapled vessels.
Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 26209484     DOI: 10.1016/j.athoracsur.2015.04.063

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  2 in total

1.  Technological innovation in video-assisted thoracic surgery.

Authors:  Mehmet Oğuzhan Özyurtkan; Erkan Kaba; Alper Toker
Journal:  J Vis Surg       Date:  2017-02-15

Review 2.  Advances and safe use of energy devices in lung cancer surgery.

Authors:  Takahiro Homma
Journal:  Gen Thorac Cardiovasc Surg       Date:  2022-02-02
  2 in total