Literature DB >> 26208066

Effect of Smear Layers Created by Different Burs on Durability of Self-Etching Adhesive Bond to Dentin of Primary Teeth.

P Rirattanapong, P Senawongse, C Harnirattisal, W Wunsiw.   

Abstract

AIM: The aim of this study was to evaluate the effects of a smear layer generated by a high-speed diamond or carbide bur on the durability of microtensile bond strength (μTBS) of a self-etching adhesive to primary dentin. STUDY
DESIGN: Flat occlusal dentin surfaces of 105 human primary molars were exposed using 600 grit silicon carbide paper before being divided into 2 groups for further grinding with either a highspeed diamond or carbide bur. Ten prepared dentin surfaces treated by each bur were evaluated for the characteristics of the smear layer using a scanning electron microscope (SEM). Seventy-five specimens from each bur-prepared group were applied with a 2-step self-etching adhesive (Clearfil SE Bond(®)) then built up with a resin composite. Each bonded specimen was sectioned into a 1-mm thick slab and trimmed to a dumbbell shape with a cross-sectional area of approximately 1 mm(2). All slabs were divided into 3 groups (n=25) according to 3 storage times of 24 hrs, 3 months, and 6 months, in distilled water at 37°C. After storage, the μTBS was determined using a universal testing machine. All fracture specimens were prepared for observation of failure modes. Ten bonded specimens of each bur group were prepared for observation of the resin-dentin interface using an SEM. Smear-layer thickness, μTBS, and failure mode distributions were statistically analyzed.
RESULTS: The high speed carbide bur created a significantly thinner smear layer than the diamond bur (p < 0.05). Dentin surfaces treated with a high-speed carbide bur generally obtained significantly higher μTBS than the diamond bur group (p < 0.05). The μTBS gradually decreased over time such that specimens stored for 6 months had significantly lower bond strength than those stored for 24 hrs (p < 0.05). Self-etching adhesive created a hybrid layer of the same thickness when prepared with either a carbide bur or diamond bur, but the carbide bur group had longer and more resin tags.
CONCLUSION: Highspeed carbide bur groups had a higher μTBS than diamond bur groups for all storage times, and bond strengths decreased over time in both substrate groups. The use of a carbide bur produced a thinner smear layer and therefore is recommended when using this 2-step self-etching adhesive to bond the resin composite to primary dentin.

Entities:  

Keywords:  bond strength; burs; hybrid layer; primary dentin; self-etching adhesive; smear layers

Mesh:

Substances:

Year:  2015        PMID: 26208066     DOI: 10.17796/1053-4628-39.3.224

Source DB:  PubMed          Journal:  J Clin Pediatr Dent        ISSN: 1053-4628            Impact factor:   1.065


  2 in total

1.  Influence of Polishing Methods on the Bonding Effectiveness and Durability of Different Resin Cements to Dentin.

Authors:  Lingyan Ren; Mingfei Li; Yahui Pan; Xiangfeng Meng
Journal:  Biomed Res Int       Date:  2018-02-28       Impact factor: 3.411

2.  Spectrophotometric analysis evaluating apical microleakage in retrograde filling using GIC, MTA and biodentine: an in-vitro study.

Authors:  Manisha Nepal; Snigdha Shubham; Rupam Tripathi; Jwolan Khadka; Deepa Kunwar; Vanita Gautam; Narayan Gautam
Journal:  BMC Oral Health       Date:  2020-02-03       Impact factor: 2.757

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.