Literature DB >> 2620690

How critical is frame selection in quantitative coronary angiographic studies?

J H Reiber1, P van Eldik-Helleman, C J Kooijman, J G Tijssen, P W Serruys.   

Abstract

To analyse quantitatively a coronary arterial segment from a cineangiogram, an end-diastolic or neighbouring frame is usually selected. However, different cardiologists may select other (although usually neighbouring) frames, even when the same selection criteria are followed. It is also possible that the frames are selected from different cardiac cycles. In this study the effects of such phase shifts on the reproducibility of the quantitative measurements were studied. In a total of 38 consecutive patient films obtained at a filmspeed of 25 frames s-1, the frame phi demonstrating the severity of a lesion optimally as judged by a senior cardiologist, the three preceding frames, the three following frames and one frame exactly one cycle prior to or following frame phi were selected; frame phi was always chosen in the end-diastolic phase of the cardiac cycle. In each film one coronary arterial segment with a focal lesion was analysed quantitatively in these total of 8 frames with the Cardiovascular Angiography Analysis System (CAAS). No significant differences were found in the mean difference and the standard deviations of the differences (variabilities) in the obstruction diameter, interpolated reference diameter, percent diameter stenosis, extent of the obstruction and area of atherosclerotic plaque obtained in the various frames with respect to frame phi. Therefore, it may be concluded that the selection of a cineframe for quantitative analysis in the end-diastolic phase of the cardiac cycle is not very critical.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1989        PMID: 2620690     DOI: 10.1093/eurheartj/10.suppl_f.54

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  4 in total

1.  Morphometry versus densitometry--a comparison by use of casts of human coronary arteries.

Authors:  P A Doriot; C Suilen; N Guggenheim; P A Dorsaz; F Chappuis; W Rutishauser
Journal:  Int J Card Imaging       Date:  1992

2.  Single cell transcriptomics based-MacSpectrum reveals novel macrophage activation signatures in diseases.

Authors:  Chuan Li; Antoine Menoret; Cullen Farragher; Zhengqing Ouyang; Christopher Bonin; Paul Holvoet; Anthony T Vella; Beiyan Zhou
Journal:  JCI Insight       Date:  2019-04-16

3.  Inter- and intra-core laboratory variability in the quantitative coronary angiography analysis for drug-eluting stent treatment and follow up.

Authors:  Shigenori Ito; Kanako Kinoshita; Akiko Endo; Ryoko Kami; Yuko Kotake; Masato Nakamura
Journal:  Ther Adv Cardiovasc Dis       Date:  2020 Jan-Dec

4.  Accuracy and precision of quantitative arteriography in the evaluation of coronary artery disease after coronary bypass surgery. A validation study.

Authors:  M Syvänne; M S Nieminen; M H Frick
Journal:  Int J Card Imaging       Date:  1994-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.