Literature DB >> 26206525

Quantitative Comparison of 2 Dual-Energy X-ray Absorptiometry Systems in Assessing Body Composition and Bone Mineral Measurements.

Wenhua Xu1, Hatim Chafi1, Beibei Guo2, Steven B Heymsfield3, Kori B Murray3, Jolene Zheng3, Guang Jia4.   

Abstract

Dual-energy X-ray absorptiometry (DXA) is widely used in body composition measurement and evaluation. Because of its numerous applications, the probability of instrument discrepancies has increased dramatically. This study quantitatively compares 2 different DXA systems. In this study, 96 subjects (60 female and 36 male, aged 19-82 years) were recruited and scanned using a General Electric Lunar iDXA and a Hologic Discovery scanner. Four measurements (percent fat, total mass, bone mineral density [BMD], and bone mineral content [BMC]) were quantitatively compared in the whole body and in specific anatomic regions (arms, legs, trunk, android, gynoid, head, ribs, and pelvis). A simple linear regression of each measurement was performed to examine the correlation between the 2 systems. Percent fat, total mass, BMC, and BMD were highly correlated between the 2 DXA systems, with correlation r values greater than 0.854 for both the whole body and the individual anatomic regions except for BMC and BMD in ribs. The high correlation between the 2 DXA systems with systematic differences enabled development of calibration equations for extending the multisystem measurements to advanced quantitative analyses.
Copyright © 2016 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Dual-energy X-ray absorptiometry; bone mineral content; bone mineral density; percent fat; quantitative comparison; total mass

Mesh:

Year:  2015        PMID: 26206525     DOI: 10.1016/j.jocd.2015.06.002

Source DB:  PubMed          Journal:  J Clin Densitom        ISSN: 1094-6950            Impact factor:   2.617


  9 in total

1.  The Relationship between Overweight and Overactive Bladder Symptoms.

Authors:  Magdaléna Hagovska; Ján Švihra; Alena Buková; Agata Horbacz; Dana Dračková; Ján Lupták; Ján Švihra
Journal:  Obes Facts       Date:  2020-05-12       Impact factor: 3.942

2.  Relation of Changes in Body Fat Distribution to Oxidative Stress.

Authors:  Heval M Kelli; Frank E Corrigan; Robert E Heinl; Devinder S Dhindsa; Muhammad Hammadah; Ayman Samman-Tahhan; Pratik Sandesara; Wesley T O'Neal; Ibhar Al Mheid; Yi-An Ko; Viola Vaccarino; Thomas R Ziegler; Laurence S Sperling; Kenneth Brigham; Dean Jones; Greg S Martin; Arshed A Quyyumi
Journal:  Am J Cardiol       Date:  2017-09-20       Impact factor: 2.778

3.  Vascular Regenerative Capacity and the Obesity Paradox in Coronary Artery Disease.

Authors:  Anurag Mehta; Qi Meng; Xiaona Li; Shivang R Desai; Melroy S D'Souza; Annie H Ho; Shabatun J Islam; Devinder S Dhindsa; Zakaria Almuwaqqat; Aditi Nayak; Ayman A Alkhoder; Ananya Hooda; Anil Varughese; Syed F Ahmad; Ali Mokhtari; Iraj Hesaroieh; Laurence S Sperling; Yi-An Ko; Edmund K Waller; Arshed A Quyyumi
Journal:  Arterioscler Thromb Vasc Biol       Date:  2021-04-15       Impact factor: 8.311

4.  Changes in truncal obesity and fat distribution predict arterial health.

Authors:  Frank E Corrigan; Heval Mohamed Kelli; Devinder S Dhindsa; Robert E Heinl; Ibhar Al Mheid; Muhammad Hammadah; Salim S Hayek; Salman Sher; Danny J Eapen; Greg S Martin; Arshed A Quyyumi
Journal:  J Clin Lipidol       Date:  2017-09-01       Impact factor: 5.365

5.  Association of adipokines, interleukin-6, and tumor necrosis factor-α concentrations with clinical characteristics and presence of spinal syndesmophytes in patients with ankylosing spondylitis: A cross-sectional study.

Authors:  Laura Gonzalez-Lopez; Nicte S Fajardo-Robledo; A Miriam Saldaña-Cruz; Inocente V Moreno-Sandoval; David Bonilla-Lara; Soraya Zavaleta-Muñiz; Arnulfo Hernan Nava-Zavala; Paulina Hernandez-Cuervo; Alberto Rocha-Muñoz; Norma Alejandra Rodriguez-Jimenez; Maria L Vazquez-Villegas; J Francisco Muñoz-Valle; Mario Salazar-Paramo; Ernesto G Cardona-Muñoz; Jorge I Gamez-Nava
Journal:  J Int Med Res       Date:  2017-05-23       Impact factor: 1.671

6.  Muscle mass measurements in hip fracture patients and control general population depending on dual-energy X-ray absorptiometry device used: The General Electric Lunar and Hologic systems.

Authors:  Jun-Ku Lee; Seong-Eun Byun; Minki Lee; Gotak Kim; Eugene Baek; Soo-Hong Han
Journal:  Osteoporos Sarcopenia       Date:  2020-05-23

7.  Comparison of Two DXA Systems, Hologic Horizon W and GE Lunar Prodigy, for Assessing Body Composition in Healthy Korean Adults.

Authors:  Seung Shin Park; Soo Lim; Hoyoun Kim; Kyoung Min Kim
Journal:  Endocrinol Metab (Seoul)       Date:  2021-12-16

8.  The Effect of Lower Body Anaerobic Pre-Loading on Upper Body Ergometer Time Trial Performance.

Authors:  Priit Purge; Dmitri Valiulin; Allar Kivil; Alexander Müller; Gerhard Tschakert; Jaak Jürimäe; Peter Hofmann
Journal:  Sports (Basel)       Date:  2021-05-31

9.  Is Sarcopenia a Potential Risk Factor for Distal Radius Fracture? Analysis Using Propensity Score Matching.

Authors:  Jun-Ku Lee; Byung-Ho Yoon; Chi Hoon Oh; Jung Gon Kim; Soo-Hong Han
Journal:  J Bone Metab       Date:  2018-05-31
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.