Literature DB >> 26204485

Droplet spray ionization from a glass microscope slide: real-time monitoring of ethylene polymerization.

Jie Jiang1, Hong Zhang2, Ming Li3, Maria T Dulay4, Andrew J Ingram4, Na Li1, Hong You2, Richard N Zare4.   

Abstract

Ambient ionization mass spectrometry is achieved in a simple manner by loading a sample solution onto a corner of a microscope cover glass positioned in front of the inlet to a mass spectrometer and applying a high voltage to the sample. The resulting stream of charged droplets is stable, has no contamination from the substrate platform, and can be used repeatedly. The utility of droplet spray for in situ analysis and real-time monitoring of chemical reactions was demonstrated by the bis(cyclopentadienyl)zirconium dichloride (zirconocene dichloride)/methylaluminoxane, Cp2ZrCl2/MAO, homogeneously catalyzed polymerization of ethylene in various solutions. Reaction times ranged from seconds to minutes, and catalytically active species and polymeric products of ethylene were acquired and identified by tandem mass spectrometry.

Entities:  

Year:  2015        PMID: 26204485     DOI: 10.1021/acs.analchem.5b02390

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  5 in total

1.  Polymer-spray mass spectrometric detection and quantitation of hydrophilic compounds and some narcotics.

Authors:  Maria T Dulay; Richard N Zare
Journal:  Rapid Commun Mass Spectrom       Date:  2017-10-15       Impact factor: 2.419

2.  Substrate-Coated Illumination Droplet Spray Ionization: Real-Time Monitoring of Photocatalytic Reactions.

Authors:  Hong Zhang; Na Li; Dandan Zhao; Jie Jiang; Hong You
Journal:  J Am Soc Mass Spectrom       Date:  2017-05-17       Impact factor: 3.109

3.  Going beyond electrospray: mass spectrometric studies of chemical reactions in and on liquids.

Authors:  Andrew J Ingram; Cornelia L Boeser; Richard N Zare
Journal:  Chem Sci       Date:  2015-10-01       Impact factor: 9.825

4.  Biochip Spray: Simplified Coupling of Surface Plasmon Resonance Biosensing and Mass Spectrometry.

Authors:  Sweccha Joshi; Han Zuilhof; Teris A van Beek; Michel W F Nielen
Journal:  Anal Chem       Date:  2017-01-26       Impact factor: 6.986

5.  Activating peroxymonosulfate by halogenated and methylated quinones: performance and mechanism.

Authors:  Hong Zhang; Lina Qiao; Jing He; Na Li; Dongmei Zhang; Kai Yu; Hong You; Jie Jiang
Journal:  RSC Adv       Date:  2019-08-30       Impact factor: 4.036

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.