Literature DB >> 26204290

Evaluation of the Articular Cartilage of the Knee Joint Using an Isotropic Resolution 3D Fast Spin-Echo Sequence With Conventional and Radial Reformatted Images.

Cristy N Gustas1, Donna G Blankenbaker2, Alejandro Munoz Del Rio2,3, Carl S Winalski4, Richard Kijowski2.   

Abstract

OBJECTIVE: The purpose of this study was to determine whether the use of radial reformatted images could improve the diagnostic performance of a 3D fast spin-echo (FSE) sequence for detecting surgically confirmed cartilage lesions within the knee joint.
MATERIALS AND METHODS: An MRI examination consisting of five 2D FSE sequences and a sagittal 3D FSE sequence was performed at 3 T on the knee joint of 150 patients who underwent subsequent knee arthroscopy, which included grading of the articular cartilage. Conventional axial, sagittal, and coronal reformatted images and radial reformatted images were created from the 3D FSE source data. Two musculoskeletal radiologists independently used the 2D FSE sequences, the 3D FSE sequence with conventional reformatted images only, and the 3D FSE sequence with both radial and conventional reformatted images at three separate sessions to grade each articular surface of the knee joint. McNemar tests were used to compare diagnostic performance for detecting cartilage lesions using arthroscopy as the reference standard.
RESULTS: The 3D FSE sequence with radial and conventional reformatted images had higher sensitivity (p < 0.001) and similar specificity (p = 0.73) to the 2D FSE sequences for detecting cartilage lesions and higher sensitivity (p < 0.001) and specificity (p = 0.002) than the 3D FSE sequence with conventional reformatted images for detecting cartilage lesions. The 3D FSE sequence with conventional reformatted images had similar sensitivity (p = 0.93) and lower specificity (p = 0.005) than did the 2D FSE sequences for detecting cartilage lesions.
CONCLUSION: A 3D FSE sequence had improved diagnostic performance compared with 2D FSE sequences for detecting cartilage lesions within the knee joint but only when using both radial and conventional reformatted images for cartilage evaluation.

Entities:  

Keywords:  3 T; MRI; cartilage; diagnostic performance; morphology

Mesh:

Year:  2015        PMID: 26204290     DOI: 10.2214/AJR.14.14265

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  3 in total

1.  Feasibility of self-gated isotropic radial late-phase MR imaging of the liver.

Authors:  Jakob Weiss; Jana Taron; Ahmed E Othman; Robert Grimm; Matthias Kuendel; Petros Martirosian; Christer Ruff; Christina Schraml; Konstantin Nikolaou; Mike Notohamiprodjo
Journal:  Eur Radiol       Date:  2016-06-08       Impact factor: 5.315

2.  Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.

Authors:  Faysal F Altahawi; Kevin J Blount; Nicholas P Morley; Esther Raithel; Imran M Omar
Journal:  Skeletal Radiol       Date:  2016-10-15       Impact factor: 2.199

3.  Cartilage Delamination Flap Mimicking a Torn Medial Meniscus.

Authors:  Gan Zhi-Wei Jonathan; Hamid Rahmatullah Bin Abd Razak; Mitra Amit Kanta
Journal:  Case Rep Orthop       Date:  2016-12-13
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.