Literature DB >> 26204081

Rapid removal of caffeine in aqueous solutions by peroxymonosulfate oxidant activated with cobalt ion.

Yunleiyu Guo1, Tingting Shen2, Chen Wang2, Jing Sun2, Xikui Wang1.   

Abstract

The removal of caffeine (CAF) in aqueous solution by peroxymonosulfate oxidant activated with cobalt ion was investigated under a variety of operating conditions. The effects of various operating parameters, such as oxone and Co²⁺ concentrations, pH value, and the coexistence of dissolved organic matter and inorganic anions on the removal of CAF have been investigated. The removal efficiency increased with the increase in the concentrations of oxone and Co²⁺ ion added. The additions of chloride, bicarbonate, and sodium humate have negative effects on the removal of CAF. Near-neutral condition (5.0 < pH < 7.0) is favorable for the removal of CAF. Based on our experiments, 100% degradation of 50 mg/L CAF can be achieved within 4 minutes under the conditions of 1.00 mM oxone and 0.10 mM Co²⁺ ion at pH 5.0-7.0.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26204081     DOI: 10.2166/wst.2015.151

Source DB:  PubMed          Journal:  Water Sci Technol        ISSN: 0273-1223            Impact factor:   1.915


  1 in total

Review 1.  Analytical tools employed to determine pharmaceutical compounds in wastewaters after application of advanced oxidation processes.

Authors:  Cristina Afonso-Olivares; Sarah Montesdeoca-Esponda; Zoraida Sosa-Ferrera; José Juan Santana-Rodríguez
Journal:  Environ Sci Pollut Res Int       Date:  2016-08-04       Impact factor: 4.223

  1 in total