Literature DB >> 26203388

X-ray luminescence computed tomography imaging based on X-ray distribution model and adaptively split Bregman method.

Dongmei Chen1, Shouping Zhu1, Xu Cao1, Fengjun Zhao1, Jimin Liang1.   

Abstract

X-ray luminescence computed tomography (XLCT) has become a promising imaging technology for biological application based on phosphor nanoparticles. There are mainly three kinds of XLCT imaging systems: pencil beam XLCT, narrow beam XLCT and cone beam XLCT. Narrow beam XLCT can be regarded as a balance between the pencil beam mode and the cone-beam mode in terms of imaging efficiency and image quality. The collimated X-ray beams are assumed to be parallel ones in the traditional narrow beam XLCT. However, we observe that the cone beam X-rays are collimated into X-ray beams with fan-shaped broadening instead of parallel ones in our prototype narrow beam XLCT. Hence we incorporate the distribution of the X-ray beams in the physical model and collected the optical data from only two perpendicular directions to further speed up the scanning time. Meanwhile we propose a depth related adaptive regularized split Bregman (DARSB) method in reconstruction. The simulation experiments show that the proposed physical model and method can achieve better results in the location error, dice coefficient, mean square error and the intensity error than the traditional split Bregman method and validate the feasibility of method. The phantom experiment can obtain the location error less than 1.1 mm and validate that the incorporation of fan-shaped X-ray beams in our model can achieve better results than the parallel X-rays.

Entities:  

Keywords:  (110.3010) Image reconstruction techniques; (340.7440) X-ray imaging

Year:  2015        PMID: 26203388      PMCID: PMC4505716          DOI: 10.1364/BOE.6.002649

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  24 in total

1.  Fluorescence diffuse optical tomography using the split Bregman method.

Authors:  J F P-J Abascal; J Chamorro-Servent; J Aguirre; S Arridge; T Correia; J Ripoll; J J Vaquero; M Desco
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

2.  Tomographic molecular imaging of x-ray-excitable nanoparticles.

Authors:  Guillem Pratx; Colin M Carpenter; Conroy Sun; Ravi P Rao; Lei Xing
Journal:  Opt Lett       Date:  2010-10-15       Impact factor: 3.776

3.  Digimouse: a 3D whole body mouse atlas from CT and cryosection data.

Authors:  Belma Dogdas; David Stout; Arion F Chatziioannou; Richard M Leahy
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

4.  Performance dependence of hybrid x-ray computed tomography/fluorescence molecular tomography on the optical forward problem.

Authors:  Damon Hyde; Ralf Schulz; Dana Brooks; Eric Miller; Vasilis Ntziachristos
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2009-04       Impact factor: 2.129

5.  Stored luminescence computed tomography.

Authors:  Wenxiang Cong; Chao Wang; Ge Wang
Journal:  Appl Opt       Date:  2014-09-01       Impact factor: 1.980

6.  Incorporating MRI structural information into bioluminescence tomography: system, heterogeneous reconstruction and in vivo quantification.

Authors:  Jun Zhang; Duofang Chen; Jimin Liang; Huadan Xue; Jing Lei; Qin Wang; Dongmei Chen; Ming Meng; Zhengyu Jin; Jie Tian
Journal:  Biomed Opt Express       Date:  2014-05-20       Impact factor: 3.732

7.  Hard X-ray-induced optical luminescence via biomolecule-directed metal clusters.

Authors:  Yasuko Osakada; Guillem Pratx; Conroy Sun; Masanori Sakamoto; Moiz Ahmad; Olga Volotskova; Qunxiang Ong; Toshiharu Teranishi; Yoshie Harada; Lei Xing; Bianxiao Cui
Journal:  Chem Commun (Camb)       Date:  2014-04-07       Impact factor: 6.222

8.  Quantitative fluorescence tomography using a combined tri-modality FT/DOT/XCT system.

Authors:  Yuting Lin; William C Barber; Jan S Iwanczyk; Werner Roeck; Orhan Nalcioglu; Gultekin Gulsen
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

9.  X-ray luminescence optical tomography imaging: experimental studies.

Authors:  Changqing Li; Kun Di; Julien Bec; Simon R Cherry
Journal:  Opt Lett       Date:  2013-07-01       Impact factor: 3.776

10.  NaGdF4:Eu3+ Nanoparticles for Enhanced X-ray Excited Optical Imaging.

Authors:  L Sudheendra; Gautom K Das; Changqing Li; Daniel Stark; Jake Cena; Simon Cherry; Ian M Kennedy
Journal:  Chem Mater       Date:  2014-02-17       Impact factor: 9.811

View more
  6 in total

1.  Sensitivity study of x-ray luminescence computed tomography.

Authors:  Michael C Lun; Wei Zhang; Changqing Li
Journal:  Appl Opt       Date:  2017-04-10       Impact factor: 1.980

2.  Multiple pinhole collimator based X-ray luminescence computed tomography.

Authors:  Wei Zhang; Dianwen Zhu; Michael Lun; Changqing Li
Journal:  Biomed Opt Express       Date:  2016-06-03       Impact factor: 3.732

3.  Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method.

Authors:  Guanglei Zhang; Fei Liu; Jie Liu; Jianwen Luo; Yaoqin Xie; Jing Bai; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2016-08-26       Impact factor: 10.048

4.  Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals.

Authors:  Dongmei Chen; Fanzhen Meng; Fengjun Zhao; Cao Xu
Journal:  Biomed Res Int       Date:  2016-10-27       Impact factor: 3.411

5.  Method for improving the spatial resolution of narrow x-ray beam-based x-ray luminescence computed tomography imaging.

Authors:  Yueming Zhang; Michael C Lun; Changqing Li; Zhongxing Zhou
Journal:  J Biomed Opt       Date:  2019-08       Impact factor: 3.170

6.  A Finite Element Mesh Regrouping Strategy-Based Hybrid Light Transport Model for Enhancing the Efficiency and Accuracy of XLCT.

Authors:  Yanqiu Liu; Xiangong Hu; Mengxiang Chu; Hongbo Guo; Jingjing Yu; Xiaowei He
Journal:  Front Oncol       Date:  2022-01-17       Impact factor: 6.244

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.