Literature DB >> 26200202

Portable Detection of Melamine in Milk Using a Personal Glucose Meter Based on an in Vitro Selected Structure-Switching Aptamer.

Chunmei Gu1, Tian Lan, Hanchang Shi1, Yi Lu.   

Abstract

Melamine detection in milk and other foods has attracted much attention since the discovery that melamine-adulterated food causes severe kidney damage. Although many methods have been developed to detect melamine, few methods can provide quantitative results using an affordable and portable device that is suitable for home use or field application. To achieve this goal, we herein report the first in vitro selection of a melamine responsive aptamer using a structure-switching method. A personal glucose meter (PGM) based melamine sensor was designed and subsequently tested using the newly isolated aptamer. Conversion of melamine concentration to glucose amount was achieved by including an invertase-conjugated DNA that is complementary to part of the aptamer. Melamine binding triggers the release of the invertase-DNA conjugate, which hydrolyzes sucrose into glucose. The glucose produced is then measured directly using an off-the-shelf PGM. The described sensor shows high selectivity for melamine against several closely related melamine analogues, such as cyanuric acid, ammeline, and ammelide, and has low detection limits of 0.33 μM (or 41.1 ppb) in buffer and 0.53 μM (or 67.5 ppb) in 80% whole milk without any pretreatment. The detection limits meet the threshold of 2.5 ppm for non-infant-formula products and 1 ppm for melamine in infant milk products as defined by the U.S. Food and Drug Administration (FDA). In addition to the PGM sensor demonstrated here, the same aptamer can be converted into other types of sensors with different signal outputs, allowing portable detection of melamine under a variety of conditions.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26200202     DOI: 10.1021/acs.analchem.5b01085

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  19 in total

1.  Multiplexed Instrument-Free Bar-Chart SpinChip Integrated with Nanoparticle-Mediated Magnetic Aptasensors for Visual Quantitative Detection of Multiple Pathogens.

Authors:  Xiaofeng Wei; Wan Zhou; Sharma T Sanjay; Jie Zhang; Qijie Jin; Feng Xu; Delfina C Dominguez; XiuJun Li
Journal:  Anal Chem       Date:  2018-08-01       Impact factor: 6.986

Review 2.  Advances and Challenges in Small-Molecule DNA Aptamer Isolation, Characterization, and Sensor Development.

Authors:  Haixiang Yu; Obtin Alkhamis; Juan Canoura; Yingzhu Liu; Yi Xiao
Journal:  Angew Chem Int Ed Engl       Date:  2021-02-09       Impact factor: 15.336

3.  Coupling Sensitive Nucleic Acid Amplification with Commercial Pregnancy Test Strips.

Authors:  Yan Du; Arti Pothukuchy; Jimmy D Gollihar; Armin Nourani; Bingling Li; Andrew D Ellington
Journal:  Angew Chem Int Ed Engl       Date:  2016-12-19       Impact factor: 15.336

Review 4.  Overcoming Major Barriers to Developing Successful Sensors for Practical Applications Using Functional Nucleic Acids.

Authors:  JingJing Zhang; Tian Lan; Yi Lu
Journal:  Annu Rev Anal Chem (Palo Alto Calif)       Date:  2022-02-25       Impact factor: 12.400

5.  Translating in vitro diagnostics from centralized laboratories to point-of-care locations using commercially-available handheld meters.

Authors:  JingJing Zhang; Tian Lan; Yi Lu
Journal:  Trends Analyt Chem       Date:  2019-12-23       Impact factor: 12.296

Review 6.  Transforming the blood glucose meter into a general healthcare meter for in vitro diagnostics in mobile health.

Authors:  Tian Lan; Jingjing Zhang; Yi Lu
Journal:  Biotechnol Adv       Date:  2016-03-03       Impact factor: 14.227

Review 7.  Point-of-Care Diagnostics: Recent Developments in a Connected Age.

Authors:  Samiksha Nayak; Nicole R Blumenfeld; Tassaneewan Laksanasopin; Samuel K Sia
Journal:  Anal Chem       Date:  2016-12-13       Impact factor: 6.986

8.  Biocomputing for Portable, Resettable, and Quantitative Point-of-Care Diagnostics: Making the Glucose Meter a Logic-Gate Responsive Device for Measuring Many Clinically Relevant Targets.

Authors:  Jingjing Zhang; Yi Lu
Journal:  Angew Chem Int Ed Engl       Date:  2018-07-09       Impact factor: 15.336

Review 9.  Point-of-care diagnostics for niche applications.

Authors:  Brian M Cummins; Frances S Ligler; Glenn M Walker
Journal:  Biotechnol Adv       Date:  2016-02-01       Impact factor: 14.227

10.  DNAzyme Amplified Aptasensing Platform for Ochratoxin A Detection Using a Personal Glucose Meter.

Authors:  Songbai Zhang; Yunxia Luan; Mengyi Xiong; Jingjing Zhang; Ryan Lake; Yi Lu
Journal:  ACS Appl Mater Interfaces       Date:  2021-02-08       Impact factor: 10.383

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.