Literature DB >> 26199501

A Comparative Evaluation of the Effect of Double Casting Technique Using Functionally Generated Path and Conventional Single Casting with Respect to Functional Articulation, Patient Satisfaction and Chair Side Time, in Single Unit Molar Teeth: An In Vivo Study.

Sarfaraz Memon1.   

Abstract

A stable centric occlusal position that shows no evidence of occlusal disease should not be altered. Confirmative restorative dentistry deals with making restorations that are in harmony with existing jaw relations. Conventional techniques for construction have been unsuccessful in producing a prosthesis that can be inserted without minor intraoral occlusal adjustment. This study was conducted to evaluate the benefits of the double casting technique with FGP over the conventional casting technique. Ten patients with root canal treated maxillary molar were selected for the fabrication of metal crown. Two techniques, one involving the conventional fabrication and other using functionally generated path with double casting were used to fabricate the prosthesis. A comparison based on various parameters which was done between the two techniques. The change in the height of castings for the double casting group was less compared to the conventional group and was highly statistically significant (P < 0.001). The time taken for occlusal correction was significantly lower in double casting group than the conventional group (P < 0.001). The patient satisfaction (before occlusal correction) indicated better satisfaction for double casting group compared to conventional (P < 0.01). The functionally generated path with double casting technique resulted in castings which had better dimensional accuracy, less occlusal correction and better patient satisfaction compared to the conventional castings.

Entities:  

Keywords:  Conventional casting; Double casting; Functionally generated path

Year:  2014        PMID: 26199501      PMCID: PMC4502019          DOI: 10.1007/s13191-014-0379-6

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  8 in total

1.  Occlusal management in conformative dentistry.

Authors:  F V Celenza; H Litvak
Journal:  J Prosthet Dent       Date:  1976-08       Impact factor: 3.426

2.  Characterization of noble metal implant cylinders: as-received cylinders and cast interfaces with noble metal alloys.

Authors:  A B Carr; W A Brantley
Journal:  J Prosthet Dent       Date:  1996-01       Impact factor: 3.426

3.  Fabrication of fixed partial dentures using functionally generated path technique and double casting.

Authors:  E Prashanti; Suresh Sajjan; Jagan Mohan Reddy
Journal:  Indian J Dent Res       Date:  2009 Oct-Dec

4.  Double-casting method for fixed prosthodontics with functionally generated path.

Authors:  S Minagi; T Tanaka; T Sato; T Matsunaga
Journal:  J Prosthet Dent       Date:  1998-02       Impact factor: 3.426

5.  A comparison of the accuracy of patterns processed from an inlay casting wax, an auto-polymerized resin and a light-cured resin pattern material.

Authors:  Praveen Rajagopal; Vidya Chitre; Meena A Aras
Journal:  Indian J Dent Res       Date:  2012 Mar-Apr

6.  Modifications of functionally generated path procedures.

Authors:  E M Zimmermann
Journal:  J Prosthet Dent       Date:  1966 Nov-Dec       Impact factor: 3.426

7.  A modified functionally generated path technique for making maxillary posterior ceramometal restorations.

Authors:  N M Kafandaris
Journal:  J Prosthet Dent       Date:  1981-07       Impact factor: 3.426

8.  Fabrication of a functionally generated, implant-retained fixed partial denture.

Authors:  Alan J Sutton; Donald W Sheets; Douglas E Ford
Journal:  J Prosthodont       Date:  2003-12       Impact factor: 2.752

  8 in total
  1 in total

1.  Occlusion and Disocclusion Time Changes in Single Unit Crowns Designed by Functional Generated Path Technique: A Randomised Clinical Trial.

Authors:  Ping-Ting Lin; Yang Jiao; San-Jun Zhao; Fu Wang; Ling Li; Fan Yu; Min Tian; Hao-Han Yu; Ji-Hua Chen
Journal:  Sci Rep       Date:  2017-03-24       Impact factor: 4.379

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.