| Literature DB >> 2619836 |
P Watson, W G Kernohan, R A Mollan.
Abstract
The familiar cracking sounds produced by distraction of the metacarpophalangeal joints were studied using accelerometers and a computerized signal analysis system. The joints were distracted in a controlled manner using a motorized device which simultaneously monitored the load on the joint and its extension. The load and extension parameters and those from the signal analysis were used to examine diurnal variation, the effects of multiple distractions, distraction speed, hand temperature and loading between distractions, and to show that in many cases, the energy contained in a crack signal, expressed as a ratio of the articular cartilage volume, exceeded a known level needed to produce articular cartilage damage.Entities:
Mesh:
Year: 1989 PMID: 2619836 DOI: 10.1243/PIME_PROC_1989_203_019_01
Source DB: PubMed Journal: Proc Inst Mech Eng H ISSN: 0954-4119 Impact factor: 1.617