Literature DB >> 26194122

A case of perioperative glucose control by using an artificial pancreas in a patient with glycogen storage disease.

Tomoaki Yatabe1, Ryu Nakamura2, Hiroyuki Kitagawa3, Masaya Munekage3, Kazuhiro Hanazaki4.   

Abstract

A 57-year-old woman was diagnosed with type I glycogen storage disease in her twenties. She had undergone hepatectomy under general anesthesia with epidural anesthesia. Fifty minutes after the induction of anesthesia, a 20-gauge venous catheter was inserted in the patient's right hand, and an artificial pancreas (STG-55, Nikkiso Co., Tokyo, Japan) was connected for continuous glucose monitoring and automatic glucose control. Insulin was infused when the blood glucose level reached 120 mg/dL or higher, and glucose was infused when the level fell to 100 mg/dL or lower. After the Pringle maneuver, the blood glucose level increased, and insulin was administered automatically via an artificial pancreas. Hypoglycemia did not occur during the operation. After total parenteral nutrition was started in the intensive care unit (ICU), the blood glucose level increased, and the artificial pancreas controlled the blood glucose level through automatic insulin administration. Thirty-four hours after admission to the ICU, the artificial pancreas was removed because the blood sampling failed. After the removal of the artificial pancreas, blood glucose level was measured every 2 h until extubation. During the ICU stay, hypoglycemia never occurred, with the average blood glucose level being 144 mg/dL. In conclusion, the use of an artificial pancreas for perioperative blood glucose management in a patient with glycogen storage disease had the beneficial effect of enabling the management of blood glucose levels without hypoglycemia.

Entities:  

Keywords:  Artificial pancreas; Glycogen storage disease; Perioperative management

Mesh:

Substances:

Year:  2015        PMID: 26194122     DOI: 10.1007/s10047-015-0855-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

1.  Bispectral index may not reflect the depth of anaesthesia in a patient with glycogen storage disease type I.

Authors:  X Yu; Y Huang; J Du
Journal:  Br J Anaesth       Date:  2009-10       Impact factor: 9.166

2.  Variability of blood glucose concentration and short-term mortality in critically ill patients.

Authors:  Moritoki Egi; Rinaldo Bellomo; Edward Stachowski; Craig J French; Graeme Hart
Journal:  Anesthesiology       Date:  2006-08       Impact factor: 7.892

3.  The evaluation of the ability of closed-loop glycemic control device to maintain the blood glucose concentration in intensive care unit patients.

Authors:  Tomoaki Yatabe; Rie Yamazaki; Hiroyuki Kitagawa; Takehiro Okabayashi; Koichi Yamashita; Kazuhiro Hanazaki; Masataka Yokoyama
Journal:  Crit Care Med       Date:  2011-03       Impact factor: 7.598

4.  Anaesthetic management of a patient with glycogen storage disease type 1b.

Authors:  Z Shenkman; Y Golub; S Meretyk; Y Shir; D Landau; E H Landau
Journal:  Can J Anaesth       Date:  1996-05       Impact factor: 5.063

5.  Continuous glucose monitoring in the treatment of obesity in patients with glycogen storage disease type Ia.

Authors:  Betty Korljan Jelaska; Sanja Baršić Ostojić; Nina Berović; Višnja Kokić
Journal:  Endocrinol Diabetes Metab Case Rep       Date:  2013-12-01

6.  Computerized intensive insulin dosing can mitigate hypoglycemia and achieve tight glycemic control when glucose measurement is performed frequently and on time.

Authors:  Rattan Juneja; Corbin P Roudebush; Stanley A Nasraway; Adam A Golas; Judith Jacobi; Joni Carroll; Deborah Nelson; Victor J Abad; Samuel J Flanders
Journal:  Crit Care       Date:  2009-10-12       Impact factor: 9.097

7.  Effect of intensive insulin therapy using a closed-loop glycemic control system in hepatic resection patients: a prospective randomized clinical trial.

Authors:  Takehiro Okabayashi; Isao Nishimori; Hiromichi Maeda; Koichi Yamashita; Tomoaki Yatabe; Kazuhiro Hanazaki
Journal:  Diabetes Care       Date:  2009-05-12       Impact factor: 19.112

  7 in total
  3 in total

Review 1.  Journal of Artificial Organs 2016: the year in review : Journal of Artificial Organs Editorial Committee.

Authors:  Y Sawa; G Matsumiya; K Matsuda; E Tatsumi; T Abe; K Fukunaga; S Ichiba; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2017-02-14       Impact factor: 1.731

Review 2.  Management of Type 1 Diabetes in the Hospital Setting.

Authors:  Carlos E Mendez; Guillermo E Umpierrez
Journal:  Curr Diab Rep       Date:  2017-09-14       Impact factor: 4.810

3.  Impact of using a perioperative artificial endocrine pancreas in pancreatic resection.

Authors:  Toshiaki Yoshimoto; Tetsuya Ikemoto; Yuji Morine; Satoru Imura; Yu Saito; Shinichiro Yamada; Katsuki Miyazaki; Yukako Takehara; Mitsuo Shimada
Journal:  Ann Gastroenterol Surg       Date:  2020-07-18
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.