Literature DB >> 26193162

Development of traceable measurement of the diffuse optical properties of solid reference standards for biomedical optics at National Institute of Standards and Technology.

Paul Lemaillet, Jean-Pierre Bouchard, David W Allen.   

Abstract

The development of a national reference instrument dedicated to the measurement of the scattering and absorption properties of solid tissue-mimicking phantoms used as reference standards is presented. The optical properties of the phantoms are measured with a double-integrating sphere setup in the steady-state domain, coupled with an inversion routine of the adding-doubling procedure that allows for the computation of the uncertainty budget for the measurements. The results are compared to the phantom manufacturer's values obtained by a time-resolved approach. The results suggest that the agreement between these two independent methods is within the estimated uncertainties. This new reference instrument will provide optical biomedical research laboratories with reference values for absolute diffuse optical properties of phantom materials.

Mesh:

Year:  2015        PMID: 26193162     DOI: 10.1364/AO.54.006118

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  6 in total

1.  Comparison of Bidirectional Transmittance Distribution Function (BTDF) Measurements on Fused Silica and Sintered Polytetrafluoroethylene Diffusers.

Authors:  James J Butler; Georgi T Georgiev; Catherine C Cooksey
Journal:  Metrologia       Date:  2019       Impact factor: 3.157

2.  Correction of an adding-doubling inversion algorithm for the measurement of the optical parameters of turbid media.

Authors:  Paul Lemaillet; Catherine C Cooksey; Jeeseong Hwang; Heidrun Wabnitz; Dirk Grosenick; Lin Yang; David W Allen
Journal:  Biomed Opt Express       Date:  2017-12-04       Impact factor: 3.732

3.  Algorithm for rapid determination of optical scattering parameters.

Authors:  Zachary H Levine; Richelle H Streater; Anne-Michelle R Lieberson; Adam L Pintar; Catherine C Cooksey; Paul Lemaillet
Journal:  Opt Express       Date:  2017-10-30       Impact factor: 3.894

4.  Goniometric and hemispherical reflectance and transmittance measurements of fused silica diffusers.

Authors:  Paul Lemaillet; Heather J Patrick; Thomas A Germer; Leonard Hanssen; B Carol Johnson; Georgi T Georgiev
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-09-01

5.  National Institute of Standards and Technology measurement service of the optical properties of biomedical phantoms: Current status.

Authors:  Paul Lemaillet; Catherine C Cooksey; Zachary H Levine; Adam L Pintar; Jeeseong Hwang; David W Allen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-24

Review 6.  Review of consensus test methods in medical imaging and current practices in photoacoustic image quality assessment.

Authors:  Jorge Palma-Chavez; T Joshua Pfefer; Anant Agrawal; Jesse V Jokerst; William C Vogt
Journal:  J Biomed Opt       Date:  2021-09       Impact factor: 3.170

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.