Literature DB >> 26187600

Can rotational alignment of total knee arthroplasty be measured on MRI?

Mirco Sgroi1, M Faschingbauer2, K Javaheripour-Otto2, H Reichel2, T Kappe2.   

Abstract

BACKGROUND AND
PURPOSE: The aim of this study was to investigate the potential of MRI to determine rotational alignment after TKA in comparison to the gold standard, CT.
METHODS: Rotational alignment was measured in the transverse plane on CT and MR-images in 14 patients prior to TKA revision. Differences between CT and MRI measurements were analysed.
RESULTS: There was a strong correlation between CT and MRI measurements for both the tibial (r = 0.929) and femoral (r = 0.942) components with a mean difference of 0.47 ± 1.3 and 0.13 ± 3.2 degrees, respectively.
INTERPRETATION: Despite artefact formation, it can be concluded that the rotational alignment of metallic TKA components can be measured by MRI as accurately as by CT.

Entities:  

Keywords:  AP Knee-recording; CT; MRI; Rotational alignment; Total knee arthroplasty

Mesh:

Year:  2015        PMID: 26187600     DOI: 10.1007/s00402-015-2289-4

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  2 in total

1.  MRI as Diagnostic Modality for Analyzing the Problematic Knee Arthroplasty: A Systematic Review.

Authors:  Femke F Schröder; Corine E Post; Frank-Christiaan B M Wagenaar; Nico Verdonschot; Rianne M H A Huis In't Veld
Journal:  J Magn Reson Imaging       Date:  2019-07-22       Impact factor: 4.813

2.  The diagnostic potential of low-field MRI in problematic total knee arthroplasties - a feasibility study.

Authors:  Femke F Schröder; Corine E Post; Sjoerd M van Raak; Frank F J Simonis; Frank-Christiaan B M Wagenaar; Rianne M H A Huis In't Veld; Nico Verdonschot
Journal:  J Exp Orthop       Date:  2020-07-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.