Literature DB >> 26186822

In situ observation and analysis of ultrasonic capillary effect in molten aluminium.

I Tzanakis1, W W Xu2, D G Eskin1, P D Lee2, N Kotsovinos3.   

Abstract

An in situ synchrotron radiographic study of a molten Al-10 wt% Cu alloy under the influence of an external ultrasonic field was carried out using the Diamond-Manchester Branchline pink X-ray imaging at the Diamond Light Source in UK. A bespoke test rig was used, consisting of an acoustic transducer with a titanium sonotrode coupled with a PID-controlled resistance furnace. An ultrasonic frequency of 30 kHz, with a peak to peak amplitude at 140 microns, was used, producing a pressure output of 16.9 MPa at the radiation surface of the 1-mm diameter sonotrode. This allowed quantification of not only the cavitation bubble formation and collapse, but there was also evidence of the previously hypothesised ultrasonic capillary effect (UCE), providing the first direct observations of this phenomenon in a molten metallic alloy. This was achieved by quantifying the re-filling of a pre-existing groove in the shape of a tube (which acted as a micro-capillary channel) formed by the oxide envelope of the liquid sample. Analytical solutions of the flow suggest that the filling process, which took place in very small timescales, was related to micro-jetting from the collapsing cavitation bubbles. In addition, a secondary mechanism of liquid penetration through the groove, which is related with the density distribution of the oxides inside the groove, and practically to the filtration of aluminium melt from oxides, was revealed. The observation of the almost instantaneous re-filling of a micro-capillary channel with the metallic melt supports the hypothesised sono-capillary effect in technologically important liquids other than water, like metallic alloys with substantially higher surface tension and density. Crown
Copyright © 2015. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cavitation; Liquid metal; Melt-filtration; Micro jet; Oxide; Sono-capillary

Year:  2015        PMID: 26186822     DOI: 10.1016/j.ultsonch.2015.04.029

Source DB:  PubMed          Journal:  Ultrason Sonochem        ISSN: 1350-4177            Impact factor:   7.491


  4 in total

1.  Effect of Ultrasonic-Assisted Modification Treatment on the Microstructure and Properties of A356 Alloy.

Authors:  Xinyi Hu; Dongfu Song; Huiping Wang; Yiwang Jia; Haiping Zou; Mingjuan Chen
Journal:  Materials (Basel)       Date:  2022-05-22       Impact factor: 3.748

2.  Effects of Ultrasonic Introduced by L-Shaped Ceramic Sonotrodes on Microstructure and Macro-Segregation of 15t AA2219 Aluminum Alloy Ingot.

Authors:  Tao Zeng; YaJun Zhou
Journal:  Materials (Basel)       Date:  2019-09-27       Impact factor: 3.623

3.  Numerical Modelling of the Ultrasonic Treatment of Aluminium Melts: An Overview of Recent Advances.

Authors:  Bruno Lebon; Iakovos Tzanakis; Koulis Pericleous; Dmitry Eskin
Journal:  Materials (Basel)       Date:  2019-10-06       Impact factor: 3.623

4.  Ultrasonic-Assisted Dispersion of ZnO Nanoparticles to Sn-Bi Solder: A Study on Microstructure, Spreading, and Mechanical Properties.

Authors:  Sri Harini Rajendran; Hyejun Kang; Jae Pil Jung
Journal:  J Mater Eng Perform       Date:  2021-02-10       Impact factor: 1.819

  4 in total