Alterations in Ultrasound Scattering Following Thermal Ablation in ex vivo Bovine Liver.

Nicholas Rubert1, Tomy Varghese2.   

Abstract

Thermal ablation is a minimally invasive cancer treatment which has been rapidly gaining clinical acceptance. It is well known that thermal ablation increases the acoustic attenuation and shear modulus of tissue. In this work, we examine changes to the spatial distribution of scatterers in liver tissue following thermal ablation. Acoustic scatterers within liver tissue have frequently been modeled as pseudo-periodic. The positions of pseudo-periodic scatterers have been Gamma distributed along the beam dimension, and these scatterers are characterized by their mean scatterer spacing (MSS). Prior work have demonstrated significant changes in MSS due to diffuse liver disease, such as steatosis progressing to cirrhosis. However, relatively few results have been reported regarding changes in MSS following thermal ablation. In this study, we estimated MSS in ex vivo bovine liver by detecting local maxima in spectral coherence functions calculated using Thomson's multi-taper method. We examined a large number of uncorrelated regions of interest recorded from five normal bovine livers (~300 images from each animal). We also examined a large number of ROI's from five bovine livers following thermal coagulation. All bovine livers were obtained from a commercial meat production facility immediately following animal sacrifice and imaged within 12 hours. Thermal coagulation was induced by heating liver in saline water baths at 80° C for 45 minutes. For normal, unheated liver an MSS of approximately 1.5 mm was estimated. Following thermal ablation, an MSS of approximately 0.5 mm in thermally coagulated tissue was obtained. Frequently, studies estimating MSS in liver tissue provide an MSS estimate regardless of the state of tissue. Authors rarely present what their MSS estimation algorithm would produce if it were applied to tissue which is better modeled as a collection of uniformly, randomly distributed scatterers lacking periodicity. In this study, we found that thermal coagulation results in a loss of periodicity. The MSS of 0.5 mm corresponds to the value that a spectral coherence-based MSS algorithm would produce if presented with a signal that was generated from uniform, randomly distributed scatterers.

Entities:  

Keywords:  MSS; spectral coherence; thermal ablation

Year:  2014        PMID: 26185596      PMCID: PMC4500940          DOI: 10.1109/ULTSYM.2014.0473

Source DB:  PubMed          Journal:  IEEE Int Ultrason Symp        ISSN: 1948-5719


  6 in total

Review 1.  Image-guided radiofrequency tumor ablation: challenges and opportunities--part I.

Authors:  S Nahum Goldberg; D E Dupuy
Journal:  J Vasc Interv Radiol       Date:  2001-09       Impact factor: 3.464

2.  Monitoring stiffness changes in lesions after radiofrequency ablation at different temperatures and durations of ablation.

Authors:  Shyam Bharat; Udomchai Techavipoo; Miklos Z Kiss; Wu Liu; Tomy Varghese
Journal:  Ultrasound Med Biol       Date:  2005-03       Impact factor: 2.998

3.  A frequency domain model for generating B-mode images with array transducers.

Authors:  Y Li; J A Zagzebski
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1999       Impact factor: 2.725

4.  Ultrasound properties of liver tissue during heating.

Authors:  M R Gertner; B C Wilson; M D Sherar
Journal:  Ultrasound Med Biol       Date:  1997       Impact factor: 2.998

5.  Characterization of tissue microstructure scatterer distribution with spectral correlation.

Authors:  T Varghese; K D Donohue
Journal:  Ultrason Imaging       Date:  1993-07       Impact factor: 1.578

6.  Mean scatterer spacing estimation using multi-taper coherence.

Authors:  Nicholas Rubert; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-06       Impact factor: 2.725

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.