Literature DB >> 26183818

Chylothorax and chylous ascites. Clinical utility of planar scintigraphy and tomographic imaging with SPECT/CT.

M Weiss1, F Schwarz, J Wallmichrath, R Baumeister, A Frick, P Bartenstein, A Rominger.   

Abstract

UNLABELLED: The aim was to analyze conventional planar scintigraphy and SPECT/CT in patients clinically suspicious for chylothorax or chylous ascites. Lymphoscintigraphy was performed for two reasons: first, to help diagnose chylothorax or -abdomen, by demonstrating diffuse uptake in fluid accumulations, and then secondly, to detect the site of leakage to test the prediction that additional use of SPECT/CT-technique improves upon the diagnostic value of planar lymphoscintigraphy in the baseline detection of thoraco-abdominal lymphatic disorders. PATIENTS, MATERIAL,
METHODS: From 7/2008-7/2014 a total of 24 consecutive patients (8 woman, 16 men; age, range 31-79 years) presenting with clinical symptoms suspicious for chylothorax and/or chylous ascites were examined by planar lymphoscintigraphy (n = 26) and additional tomographic SPECT/CT- (n = 22) or SPECT-technique (n = 2).
RESULTS: Chylothorax could be scintigraphically confirmed in n = 9, chylous ascites in n = 5 scintigraphies, and excluded in n = 10 patients. In all planar scintigraphy findings of pathological lymph drainage regions (n = 14), SPECT/CT delivered additional relevant information, notably the anatomic localization of the lymphatic leakage. For the baseline detection of thoraco-abdominal lymphatic transport disorders, lymphoscintigraphy showed sensitivity of 88%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 80%.
CONCLUSIONS: Our findings show that due to the particular advantages presented by tomographic separation of overlapping sources, SPECT/CT specifies better the anatomical sites, improving the localization of lymphatic leakage in aid of planning surgical re-interventions.

Entities:  

Keywords:  Chylothorax; SPECT/CT; chylous ascites; hybrid imaging; lymphoscintigraphy

Mesh:

Year:  2015        PMID: 26183818     DOI: 10.3413/Nukmed-0723-15-02

Source DB:  PubMed          Journal:  Nuklearmedizin        ISSN: 0029-5566            Impact factor:   1.379


  4 in total

Review 1.  Chylous Ascites and Lymphoceles: Evaluation and Interventions.

Authors:  Ernesto Santos; Amgad M Moussa
Journal:  Semin Intervent Radiol       Date:  2020-07-31       Impact factor: 1.513

2.  Recurrent chylous effusions and venous thrombosis: Uncommon presentation of a common condition.

Authors:  Manasvini Bhatt; Netto George; Manish Soneja; Prabhat Kumar; Surabhi Vyas; Ashutosh Biswas
Journal:  Intractable Rare Dis Res       Date:  2018-08

3.  Potential Applications of Using 68Ga-Evans Blue PET/CT in the Evaluation of Lymphatic Disorder: Preliminary Observations.

Authors:  Wei Zhang; Peilin Wu; Fang Li; Guansheng Tong; Xiaoyuan Chen; Zhaohui Zhu
Journal:  Clin Nucl Med       Date:  2016-04       Impact factor: 7.794

Review 4.  Chylous Ascites: A Review of Pathogenesis, Diagnosis and Treatment.

Authors:  Richa Bhardwaj; Haleh Vaziri; Arun Gautam; Enrique Ballesteros; David Karimeddini; George Y Wu
Journal:  J Clin Transl Hepatol       Date:  2017-12-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.