| Literature DB >> 26182096 |
Lin Zhou1,2, Shitong Long1,2,3, Biao Tang1,2, Xi Chen1,2, Fen Gao1,2, Wencui Peng1,2, Weitao Duan1,2,3, Jiaqi Zhong1,2, Zongyuan Xiong1,2, Jin Wang1,2, Yuanzhong Zhang4, Mingsheng Zhan1,2.
Abstract
We report an improved test of the weak equivalence principle by using a simultaneous 85Rb-87Rb dual-species atom interferometer. We propose and implement a four-wave double-diffraction Raman transition scheme for the interferometer, and demonstrate its ability in suppressing common-mode phase noise of Raman lasers after their frequencies and intensity ratios are optimized. The statistical uncertainty of the experimental data for Eötvös parameter η is 0.8×10(-8) at 3200 s. With various systematic errors corrected, the final value is η=(2.8±3.0)×10(-8). The major uncertainty is attributed to the Coriolis effect.Entities:
Year: 2015 PMID: 26182096 DOI: 10.1103/PhysRevLett.115.013004
Source DB: PubMed Journal: Phys Rev Lett ISSN: 0031-9007 Impact factor: 9.161