Literature DB >> 26179681

Comparing Two Diagnostic Procedures in Planning Dental Implants to Support a Mandibular Free-Ending Removable Partial Denture.

Charlotte Jensen1, Gerry M Raghoebar2, Henny J A Meijer2, Rutger Schepers2, Marco S Cune1.   

Abstract

BACKGROUND: The use of a cone beam computed tomography (CBCT) for the preoperative implant planning is increasing. A clear guideline is needed in which cases of CBCT is essential.
PURPOSE: In this study, two imaging modalities (panoramic radiograph and CBCT) are compared in preoperative implant planning in the severely resorbed mandible and the influence on the observers assessments.
MATERIALS AND METHODS: Thirty-four consecutive patients with bilateral edentulous regions in the mandible were included. The feasibility of implant placement in the premolar and molar region was judged by three observers on basis of casts either with a panoramic radiograph or a CBCT.Cohen's kappa, sensitivity and specificity rates, odds of agreement and disagreement as well as the odds ratios (ORs, ratio between odds of agreement and disagreement) were calculated per observer and overall for all observers assuming the majorities agreement as the prevailing opinion.
RESULTS: Overall outcome for premolar region revealed true-positive and true-negative rates of 90% and 0%, respectively, with Cohen's kappa (κ) = -0.04. The ORs for the three observers varied between 2.6 and 158.8, with an overall OR = 76.For the molar region, overall true-positive and true-negative rates were 65% and 22% respectively, with Cohen's κ = 0.68, representing a reasonable amount of agreement. Sensitivity and specificity as well as the ORs for individual observers were fairly consistent with an overall OR = 43.
CONCLUSION: Implant placement in the resorbed posterior mandible can be well assessed with a cast in combination with a panoramic radiograph in the vast majority of the cases. Misclassification amounts to approximately 10% to 13%. In all cases of misclassification, a critical bone height, or an unclear course of the mandibular nerve or a knife edge ridge was present. In these cases, the use of a CBCT is justified.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  cone beam CT; implants; panoramic radiograph; removable partial denture; severely resorbed posterior mandible

Mesh:

Year:  2015        PMID: 26179681     DOI: 10.1111/cid.12359

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

1.  Anatomical landmarks of mandibular interforaminal region related to dental implant placement with 3D CBCT: comparison between edentulous and dental mandibles.

Authors:  Elif Sener; Erinc Onem; Gulcan Coskun Akar; Figen Govsa; Mehmet Asim Ozer; Yelda Pinar; Ali Mert; B Guniz Baksi Sen
Journal:  Surg Radiol Anat       Date:  2017-11-09       Impact factor: 1.246

2.  Do Morphological Changes in the Anterior Mandibular Region Interfere with Standard Implant Placement? A Cone Beam Computed Tomographic Cross-Sectional Study.

Authors:  Shaimaa M Fouda; Passant Ellakany; Marwa Madi; Osama Zakaria; Fahad A Al-Harbi; Maha El Tantawi
Journal:  ScientificWorldJournal       Date:  2020-12-18

Review 3.  Indications for 3-D diagnostics and navigation in dental implantology with the focus on radiation exposure: a systematic review.

Authors:  Burkhard Kunzendorf; Hendrik Naujokat; Jörg Wiltfang
Journal:  Int J Implant Dent       Date:  2021-05-27
  3 in total