Literature DB >> 26178163

Simultaneous Determination of Methanol, Ethanol and Formic Acid in Serum and Urine by Headspace GC-FID.

Miroslava Bursová1, Tomáš Hložek2, Radomír Čabala3.   

Abstract

A simple, cost-effective headspace gas chromatography (GC) method coupled with GC with flame ionization detection for simultaneous determination of methanol, ethanol and formic acid was developed and validated for clinical and toxicological purposes. Formic acid was derivatized with an excess of isopropanol under acidic conditions to its volatile isopropyl ester while methanol and ethanol remained unchanged. The entire sample preparation procedure is complete within 6 min. The design of the experiment (the face-centered central composite design) was used for finding the optimal conditions for derivatization, headspace sampling and chromatographic separation. The calibration dependences of the method were quadratic in the range from 50 to 5,000 mg/L, with adequate accuracy (89.0-114.4%) and precision (<12%) in the serum. The new method was successfully used for determination of selected analytes in serum samples of intoxicated patients from among those affected by massive methanol poisonings in the Czech Republic in 2012.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26178163     DOI: 10.1093/jat/bkv075

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  6 in total

1.  Simultaneous measurement of formic acid, methanol and ethanol in vitreous and blood samples of postmortem by headspace GC-FID.

Authors:  Hamideh Ghorbani; Alireza Nezami; Behjat Sheikholeslami; Arya Hedjazi; Mahnaz Ahmadimanesh
Journal:  J Occup Med Toxicol       Date:  2018-01-08       Impact factor: 2.646

2.  SPME-GC/MS Analysis of Methanol in Biospecimen by Derivatization with Pyran Compound.

Authors:  Joon-Bae Lee; Yong Ae Jeong; Dae Jun Ahn; Iel Soo Bang
Journal:  Molecules       Date:  2019-12-20       Impact factor: 4.411

3.  Electrospun Silk Fibroin Scaffolds for Tissue Regeneration: Chemical, Structural, and Toxicological Implications of the Formic Acid-Silk Fibroin Interaction.

Authors:  Marco Biagiotti; Giulia Alessandra Bassani; Anna Chiarini; Valentina Teodolinda Vincoli; Ilaria Dal Prà; Cesare Cosentino; Antonio Alessandrino; Paola Taddei; Giuliano Freddi
Journal:  Front Bioeng Biotechnol       Date:  2022-01-27

4.  Fluorometric trace methanol detection in ethanol and isopropanol in a water medium for application in alcoholic beverages and hand sanitizers.

Authors:  Snigdha Roy; Sanju Das; Ambarish Ray; Partha Pratim Parui
Journal:  RSC Adv       Date:  2021-09-09       Impact factor: 4.036

5.  Processing Method for the Quantification of Methanol and Ethanol from Bioreactor Samples Using Gas Chromatography-Flame Ionization Detection.

Authors:  Jewel Ann Joseph; Simen Akkermans; Jan F M Van Impe
Journal:  ACS Omega       Date:  2022-07-08

6.  A Smart Colorimetric Platform for Detection of Methanol, Ethanol and Formic Acid.

Authors:  Mizaj Shabil Sha; Muni Raj Maurya; Mithra Geetha; Bijandra Kumar; Aboubakr M Abdullah; Kishor Kumar Sadasivuni
Journal:  Sensors (Basel)       Date:  2022-01-13       Impact factor: 3.576