Literature DB >> 26177660

Evaluation of Factor Xa-Specific Chromogenic Substrate Assays and the Determination of Pharmacokinetics of Fondaparinux.

Maiko Yuri1, Yoko Tabe2, Koji Tsuchiya1, Ryo Sadatsuki3, Jun Aoki4, Takashi Horii1, Toshiaki Iba5, Akimichi Ohsaka1.   

Abstract

Fondaparinux (FPX), a synthesized factor Xa inhibitor, is one of the most popular anticoagulants for the prevention of postoperative venous thromboembolism (VTE). Although routine monitoring is not required, the bleeding adverse events cannot be neglected, and the measurement of anti-Xa activity is expected to be monitored. The primary purpose of this study is to evaluate the performances of 2 chromogenic assays for the detection of anti-Xa activity. Furthermore, the pharmacokinetics of FPX was examined using chromogenic assays. Anti-Xa activity was measured using 2 FPX-based chromogenic substrates (S2222 and STA-Liquid Anti-Xa). The reproducibility, detection limits, linearity, and correlations between the substrates were examined using normal plasma doped with low and high concentrations of FPX formulation. In addition, anti-Xa activity in 235 clinical samples from 164 cases treated was measured, and the pharmacokinetics of FPX was evaluated. Both of the tested substrates were capable of accurately measuring the anti-Xa activity of FPX, with a lower limit of 0.05 μg/mL and a coefficient of variation of less than 10%. The repeated administration of FPX induced a gradual but significant increase in the anti-Xa activity, which was negatively correlated with body weight and estimated glomerular filtration rate. No significant correlation between the anti-Xa activity and the occurrence of postoperative VTE or bleeding event was observed. Anti-Xa activity can be successfully determined using 2 chromogenic assays and automated biochemical analyzers. The clinical significance of anti-Xa activity monitoring should be examined in the future study.
© The Author(s) 2015.

Entities:  

Keywords:  chromogenic substrate assay; factor Xa inhibitor; fondaparinux

Mesh:

Substances:

Year:  2015        PMID: 26177660     DOI: 10.1177/1076029615595878

Source DB:  PubMed          Journal:  Clin Appl Thromb Hemost        ISSN: 1076-0296            Impact factor:   2.389


  1 in total

1.  Comparison of prothrombin time tests used in the monitoring of edoxaban and their evaluation as indicators of the reversal effect.

Authors:  Toshiaki Iba; Mari Emmi; Makoto Hiki; Masataka Nagayama; Koichiro Aihara; Yoko Tabe; Maiko Yuri; Akimichi Ohsaka
Journal:  Int J Hematol       Date:  2016-03-16       Impact factor: 2.490

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.