Literature DB >> 26176595

Carbon Nanotubes Labeled with Aptamer and Horseradish Peroxidase as a Probe for Highly Sensitive Protein Biosensing by Postelectropolymerization of Insoluble Precipitates on Electrodes.

Jing Li1,2, Jingjing Wang1, Xiang Guo1, Qiong Zheng1, Jing Peng1, Hao Tang1, Shouzhuo Yao1,3.   

Abstract

Carbon nanotubes (CNTs) labeled with aptamer and horseradish peroxidase (HRP) were used as a probe to amplify the impedimetric sensing of the aptamer-protein (with thrombin as the model) interaction. The HRP-biocatalyzed oxidation of 3,3-diaminobenzidine (DAB) in the presence of H2O2 and the postelectropolymerization of insoluble precipitates produced on the electrode supports were used as a signal amplification route for the sensing process. Thrombin was sensed by aptamer 1 immobilized on a glassy carbon electrode. The multiwalled CNT-aptamer 2-HRP probe was linked to the aptamer 1-thrombin complex through the thrombin-aptamer 2 interaction. The postelectropolymerization of biocatalyzed precipitates of DAB on the electrode greatly increased the electron-transfer resistance at the electrode-solution interface. Cyclic voltammetry and electrochemical impedance spectroscopy were employed to follow the stepwise fabrication of the aptasensor and impedimetric detection of thrombin. Thrombin concentration as low as 0.05 pM could be detected by this method. In addition, the proposed impedimetric aptasensor exhibits good sensitivity (5195 Ω decade(-1)), selectivity, and reproducibility. The aptasensor also has acceptable recovery for thrombin detection in complex protein sample.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26176595     DOI: 10.1021/acs.analchem.5b00640

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  3 in total

1.  A Carbon-Based Antifouling Nano-Biosensing Interface for Label-Free POCT of HbA1c.

Authors:  Zhenhua Li; Jianyong Li; Yanzhi Dou; Lihua Wang; Shiping Song
Journal:  Biosensors (Basel)       Date:  2021-04-12

2.  An aptasensor for the label-free detection of thrombin based on turn-on fluorescent DNA-templated Cu/Ag nanoclusters.

Authors:  Baozhu Zhang; Chunying Wei
Journal:  RSC Adv       Date:  2020-09-24       Impact factor: 4.036

Review 3.  The Chemistry and Applications of Metal-Organic Frameworks (MOFs) as Industrial Enzyme Immobilization Systems.

Authors:  Allison R M Silva; Jeferson Y N H Alexandre; José E S Souza; José G Lima Neto; Paulo G de Sousa Júnior; Maria V P Rocha; José C S Dos Santos
Journal:  Molecules       Date:  2022-07-15       Impact factor: 4.927

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.