Literature DB >> 26175467

Automated three-dimensional registration of high-resolution peripheral quantitative computed tomography data to quantify size and shape changes of arthritic bone erosions.

Dominique Töpfer1, Bastian Gerner2, Stephanie Finzel3, Sebastian Kraus3, Oleg Museyko2, Georg Schett3, Klaus Engelke2.   

Abstract

OBJECTIVE: To monitor size and shape changes of bone erosions and changes in BMD in the vicinity of the erosion and in the periarticular trabecular compartment of patients with RA using high-resolution peripheral quantitative CT (HR-pQCT) imaging and to compare an automated three-dimensional (3D) image processing technique with manual measurements of erosion width and depth.
METHODS: The shape of 40 bone erosions and composition of bone around the erosions were analysed in the MCP joints of 22 RA patients both manually and by semi-automated 3D image processing at two different time points. Periosteal segmentation was performed using volume growing and morphological operations. Image registration was applied for transfer of baseline segmentations to follow-up datasets.
RESULTS: Eight erosions decreased in size, 6 increased and 28 remained stable. Increasing erosions were more spherical and smaller at baseline compared with decreasing or stable erosions. BMD in the vicinity of shrinking erosions increased, while it decreased next to expanding erosions. There was moderate agreement in the determination of erosion volume between semi-automated and manual measurements, but agreement was poor when assessing changes in volume over time.
CONCLUSION: Longitudinal changes in erosion size and shape and of BMD in the vicinity of an erosion can be measured. BMD changes are associated with progression and regression of erosions. However, the semi-automated and manual approaches did not classify longitudinal changes of erosion volume in the same way. Further research is necessary to define the nature of these differences.
© The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Keywords:  bone erosions; high-resolution peripheral computed tomography; image processing; rheumatoid arthritis

Mesh:

Substances:

Year:  2015        PMID: 26175467     DOI: 10.1093/rheumatology/kev256

Source DB:  PubMed          Journal:  Rheumatology (Oxford)        ISSN: 1462-0324            Impact factor:   7.580


  8 in total

1.  A descriptive, cross-sectional study characterizing bone erosions in rheumatoid arthritis and gout by ultrasound.

Authors:  Lucio Ventura-Ríos; Cristina Hernández-Díaz; Guadalupe Sanchez-Bringas; Eduardo Madrigal-Santillán; José Antonio Morales-González; Carlos Pineda
Journal:  Clin Rheumatol       Date:  2016-07-09       Impact factor: 2.980

2.  Analysis of bone erosions in rheumatoid arthritis using HR-pQCT: Development of a measurement algorithm and assessment of longitudinal changes.

Authors:  Kazuteru Shiraishi; Ko Chiba; Kounosuke Watanabe; Nozomi Oki; Naoki Iwamoto; Shoken Amano; Akihiko Yonekura; Masato Tomita; Masataka Uetani; Atsushi Kawakami; Makoto Osaki
Journal:  PLoS One       Date:  2022-04-26       Impact factor: 3.752

3.  Feasibility of rigid 3D image registration of high-resolution peripheral quantitative computed tomography images of healing distal radius fractures.

Authors:  Joost J A de Jong; Patrik Christen; Ryan M Plett; Roland Chapurlat; Piet P Geusens; Joop P W van den Bergh; Ralph Müller; Bert van Rietbergen
Journal:  PLoS One       Date:  2017-07-25       Impact factor: 3.240

4.  Comparative study of the inhibitory effect on bone erosion progression with denosumab treatment and conventional treatment in rheumatoid arthritis patients: study protocol for an open-label randomized controlled trial by HR-pQCT.

Authors:  Naoki Iwamoto; Shuntaro Sato; Remi Sumiyoshi; Ko Chiba; Nanami Miyamoto; Kumiko Arinaga; Makiko Kobayashi; Hiroshi Yamamoto; Makoto Osaki; Atsushi Kawakami
Journal:  Trials       Date:  2019-08-13       Impact factor: 2.279

5.  Consensus approach for 3D joint space width of metacarpophalangeal joints of rheumatoid arthritis patients using high-resolution peripheral quantitative computed tomography.

Authors:  Kathryn S Stok; Andrew J Burghardt; Stephanie Boutroy; Michiel P H Peters; Sarah L Manske; Vincent Stadelmann; Nicolas Vilayphiou; Joop P van den Bergh; Piet Geusens; Xiaojuan Li; Hubert Marotte; Bert van Rietbergen; Steven K Boyd; Cheryl Barnabe
Journal:  Quant Imaging Med Surg       Date:  2020-02

6.  An automated algorithm for the detection of cortical interruptions and its underlying loss of trabecular bone; a reproducibility study.

Authors:  M Peters; J de Jong; A Scharmga; A van Tubergen; P Geusens; D Loeffen; R Weijers; S K Boyd; C Barnabe; K S Stok; B van Rietbergen; J van den Bergh
Journal:  BMC Med Imaging       Date:  2018-05-15       Impact factor: 1.930

7.  The utility of multi-stack alignment and 3D longitudinal image registration to assess bone remodeling in rheumatoid arthritis patients from second generation HR-pQCT scans.

Authors:  Scott C Brunet; Michael T Kuczynski; Jennifer L Bhatla; Sophie Lemay; Yves Pauchard; Peter Salat; Cheryl Barnabe; Sarah L Manske
Journal:  BMC Med Imaging       Date:  2020-04-07       Impact factor: 1.930

Review 8.  The clinical application of high-resolution peripheral computed tomography (HR-pQCT) in adults: state of the art and future directions.

Authors:  J P van den Bergh; P Szulc; A M Cheung; M Bouxsein; K Engelke; R Chapurlat
Journal:  Osteoporos Int       Date:  2021-05-22       Impact factor: 4.507

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.