Nalan Kozaci1, Mehmet Oguzhan Ay2, Mehmet Akcimen3, Ikbal Sasmaz3, Gokcen Turhan3, Ali Boz3. 1. Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey. Electronic address: nalankozaci@gmail.com. 2. Adana Numune Education and Research Hospital, Department of Emergency Medicine, Adana, Turkey. 3. Antalya Education and Research Hospital, Department of Emergency Medicine, Antalya, Turkey.
Abstract
OBJECTIVE: We aimed to compare the effectiveness of point-of-care ultrasonography (POCUS) with direct radiography (DR) in the diagnosis and management of the patients with metacarpal fractures (MFs). METHODS: Patients between ages 5 and 55 years admitted to the emergency department with suspected MFs were included to the study. Emergency physicians (EPs) participating in the study were divided into 2 groups (POCUS, DR). Patients were evaluated by one of the EPs from each group. The EP performing the POCUS examination was blinded to the radiograph results. RESULTS: A total of 66 patients with MFs were included to the study. Fracture was determined in 36 (55%) patients with DR and in 37 (56%) patients with POCUS. When compared with radiography, the sensitivity of fracture detection with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 90% (95% confidence interval, 80%-98%). Sensitivity of detecting localization of the fracture with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 89% (95% confidence interval, 80%-98%). Of the patients with fracture, 69% have angulation and 24% have step-off determined with POCUS. Specificity of POCUS in the decision for treatment choice was 100%, and sensitivity was 99%. CONCLUSION: We found that POCUS could be applied easily with success by EPs in diagnosing MFs, determining the type of the fracture and required treatment methods correctly. Point-of-care US can be used to rule out a suspected MF, thereby avoiding the time and expense of radiography.
OBJECTIVE: We aimed to compare the effectiveness of point-of-care ultrasonography (POCUS) with direct radiography (DR) in the diagnosis and management of the patients with metacarpal fractures (MFs). METHODS:Patients between ages 5 and 55 years admitted to the emergency department with suspected MFs were included to the study. Emergency physicians (EPs) participating in the study were divided into 2 groups (POCUS, DR). Patients were evaluated by one of the EPs from each group. The EP performing the POCUS examination was blinded to the radiograph results. RESULTS: A total of 66 patients with MFs were included to the study. Fracture was determined in 36 (55%) patients with DR and in 37 (56%) patients with POCUS. When compared with radiography, the sensitivity of fracture detection with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 90% (95% confidence interval, 80%-98%). Sensitivity of detecting localization of the fracture with POCUS was 92%; specificity, 87%; positive predictive value, 89%; and negative predictive value, 89% (95% confidence interval, 80%-98%). Of the patients with fracture, 69% have angulation and 24% have step-off determined with POCUS. Specificity of POCUS in the decision for treatment choice was 100%, and sensitivity was 99%. CONCLUSION: We found that POCUS could be applied easily with success by EPs in diagnosing MFs, determining the type of the fracture and required treatment methods correctly. Point-of-care US can be used to rule out a suspected MF, thereby avoiding the time and expense of radiography.
Authors: Roxana Iacob; Emil Robert Stoicescu; Simona Cerbu; Daniela Iacob; Elena Amaricai; Liliana Catan; Oana Belei; Emil Radu Iacob Journal: Healthcare (Basel) Date: 2022-04-29
Authors: Djoke Douma-den Hamer; Marco H Blanker; Mireille A Edens; Lonneke N Buijteweg; Martijn F Boomsma; Sven H van Helden; Gert-Jan Mauritz Journal: PLoS One Date: 2016-05-19 Impact factor: 3.240
Authors: Teri Ann Reynolds; Stas Amato; Irene Kulola; Chuan-Jay Jeffrey Chen; Juma Mfinanga; Hendry Robert Sawe Journal: PLoS One Date: 2018-04-25 Impact factor: 3.240