Literature DB >> 26172589

A pollutant load hierarchical allocation method integrated in an environmental capacity management system for Zhushan Bay, Taihu Lake.

Shidong Liang1, Haifeng Jia2, Cong Yang3, Charles Melching4, Yongping Yuan5.   

Abstract

An environmental capacity management (ECM) system was developed to help practically implement a Total Maximum Daily Load (TMDL) for a key bay in a highly eutrophic lake in China. The ECM system consists of a simulation platform for pollutant load calculation and a pollutant load hierarchical allocation (PLHA) system. The simulation platform was developed by linking the Environmental Fluid Dynamics Code (EFDC) and Water Quality Analysis Simulation Program (WASP). In the PLHA, pollutant loads were allocated top-down in several levels based on characteristics of the pollutant sources. Different allocation methods could be used for the different levels with the advantages of each method combined over the entire allocation. Zhushan Bay of Taihu Lake, one of the most eutrophic lakes in China, was selected as a case study. The allowable loads of total nitrogen, total phosphorus, ammonia, and chemical oxygen demand were found to be 2122.2, 94.9, 1230.4, and 5260.0 t·yr(-1), respectively. The PLHA for the case study consists of 5 levels. At level 0, loads are allocated to those from the lakeshore direct drainage, atmospheric deposition, internal release, and tributary inflows. At level 1 the loads allocated to tributary inflows are allocated to the 3 tributaries. At level 2, the loads allocated to one inflow tributary are allocated to upstream areas and local sources along the tributary. At level 3, the loads allocated to local sources are allocated to the point and non-point sources from different towns. At level 4, the loads allocated to non-point sources in each town are allocated to different villages. Compared with traditional forms of pollutant load allocation methods, PLHA can combine the advantages of different methods which put different priority weights on equity and efficiency, and the PLHA is easy to understand for stakeholders and more flexible to adjust when applied in practical cases.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  EFDC; Environmental capacity management; Pollutant load hierarchical allocation; TMDL; Taihu Lake; WASP

Mesh:

Substances:

Year:  2015        PMID: 26172589     DOI: 10.1016/j.scitotenv.2015.06.116

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  4 in total

1.  Integrated waste load allocation for river water pollution control under uncertainty: a case study of Tuojiang River, China.

Authors:  Jiuping Xu; Shuhua Hou; Liming Yao; Chaozhi Li
Journal:  Environ Sci Pollut Res Int       Date:  2017-06-10       Impact factor: 4.223

2.  Pollutants' discharges and capacities: a comprehensive understanding for pollution sources and aquatic environmental medium is needed in China.

Authors:  Hong Yao
Journal:  Environ Sci Pollut Res Int       Date:  2016-06-17       Impact factor: 4.223

3.  A bi-level multiobjective optimization model for waste load allocation in rivers.

Authors:  Xuan Zhang; Jungang Luo; Jiancang Xie
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-17       Impact factor: 4.223

4.  New Framework for Dynamic Water Environmental Capacity Estimation Integrating the Hydro-Environmental Model and Load-Duration Curve Method-A Case Study in Data-Scarce Luanhe River Basin.

Authors:  Huiyu Jin; Wanqi Chen; Zhenghong Zhao; Jiajia Wang; Weichun Ma
Journal:  Int J Environ Res Public Health       Date:  2022-07-09       Impact factor: 4.614

  4 in total