Literature DB >> 26172177

Screening method for the determination of tetracyclines and fluoroquinolones in animal drinking water by liquid chromatography with diode array detector.

E Patyra, E Kowalczyk, A Grelik, M Przeniosło-Siwczyńska, K Kwiatek.   

Abstract

A liquid chromatography - diode array detector (HPLC-DAD) procedure has been developed for the determination of oxytetracycline (OTC), tetracycline (TC), chlorotetracycline (CTC), doxycycline (DC), enrofloxacin (ENR), ciprofloxacin (CIP), sarafloxacin (SAR) and flumequine (FLU) residues in animal drinking water. This method was applied to animal drinking water. Solid-phase extraction (SPE) clean-up on an Oasis HLB cartridge allowed an extract suitable for liquid chromatographic analysis to be obtained. Chromatographic separation was carried out on a C18 analytical column, using gradient elution with 0.1% trifluoroacetic acid - acetonitrile - methanol at 30°C. The flow-rate was 0.7 mL/min and the eluate was analysed at 330 nm. The whole procedure was evaluated according to the requirements of the Commission Decision 2002/657/EC, determining specificity, decision limit (CCα), detection capacity (CCβ), limit of detection (LOD), limit of quantification (LOQ), precision and accuracy during validation of the method. The recoveries of TCs and FQs from spiked samples at the levels of 10, 100 and 1000 μg/L were higher than 82%. The developed method based on HPLC-DAD has been applied for the determination of four tetracyclines and four fluoroquinolones in animal drinking water samples.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26172177     DOI: 10.1515/pjvs-2015-0037

Source DB:  PubMed          Journal:  Pol J Vet Sci        ISSN: 1505-1773            Impact factor:   0.821


  3 in total

Review 1.  Tetracyclines in Food and Feedingstuffs: From Regulation to Analytical Methods, Bacterial Resistance, and Environmental and Health Implications.

Authors:  Fabio Granados-Chinchilla; César Rodríguez
Journal:  J Anal Methods Chem       Date:  2017-01-12       Impact factor: 2.193

2.  Highly luminescent water-dispersed silicon quantum dots for fluorometric determination of oxytetracycline in milk samples.

Authors:  Hayriye Eda Şatana Kara; Burak Demİrhan; Buket Er Demİrhan
Journal:  Turk J Chem       Date:  2020-12-16       Impact factor: 1.239

3.  Optimization of a Method for Extraction and Determination of Residues of Selected Antimicrobials in Soil and Plant Samples Using HPLC-UV-MS/MS.

Authors:  Klaudia Kokoszka; Agnieszka Kobus; Sylwia Bajkacz
Journal:  Int J Environ Res Public Health       Date:  2021-01-28       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.