Candidate Reference Measurement Procedure for the Determination of (24R),25-Dihydroxyvitamin D3 in Human Serum Using Isotope-Dilution Liquid Chromatography-Tandem Mass Spectrometry.

Susan S-C Tai1, Michael A Nelson1.   

Abstract

The two major forms of vitamin D, vitamin D3 and vitamin D2, are metabolized in the liver through hydroxylation to 25-hydroxyvitamin D species, and then further hydroxylated in the kidney to various dihydroxyvitamin D species. (24R),25-Dihydroxyvitamin D3 ((24R),25(OH)2D3) is a major catabolite of 25-hydroxyvitamin D metabolism and is an important vitamin D metabolite used as a catabolism marker and indicator of kidney disease. The National Institute of Standards and Technology has recently developed a reference measurement procedure for the determination of (24R),25(OH)2D3 in human serum using isotope-dilution LC-MS/MS. The (24R),25(OH)2D3 and added deuterated labeled internal standard (24R),25(OH)2D3-d6 were extracted from serum matrix using liquid-liquid extraction prior to LC-MS/MS analysis. Chromatographic separation was performed using a fused-core C18 column. Atmospheric pressure chemical ionization in the positive ion mode and multiple reaction monitoring were used for LC-MS/MS. The accuracy of the measurement of (24R),25(OH)2D3 was evaluated by recovery studies of measuring (24R),25(OH)2D3 in gravimetrically prepared spiked samples of human serum with known (24R),25(OH)2D3 levels. The recoveries of the added (24R),25(OH)2D3 averaged 99.0% (0.8% SD), and the extraction efficiencies averaged 95% (2% SD). Excellent repeatability was demonstrated with CVs of ∼1%. The limit of quantitation at a signal-to-noise ratio of ∼10 was 0.2 ng/g. Potential isomeric interferences from other endogenous species and from impurity components of the reference standard were investigated. LC baseline resolution of (24R),25(OH)2D3 from these isomers was achieved within 35 min. This method was used for value assignment of (24R),25(OH)2D3 in Standard Reference Materials of Vitamin D Metabolites in Human Serum, which can serve as an accuracy base for routine methods used in clinical laboratories.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26171884     DOI: 10.1021/acs.analchem.5b01861

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  21 in total

1.  Vitamin D and Cardiovascular Disease: Can Novel Measures of Vitamin D Status Improve Risk Prediction and Address the Vitamin D Racial Paradox?

Authors:  Samuel M Kim; Pamela L Lutsey; Erin D Michos
Journal:  Curr Cardiovasc Risk Rep       Date:  2017-01-21

Review 2.  Vitamin D assays and the definition of hypovitaminosis D: results from the First International Conference on Controversies in Vitamin D.

Authors:  Christopher T Sempos; Annemieke C Heijboer; Daniel D Bikle; Jens Bollerslev; Roger Bouillon; Patsy M Brannon; Hector F DeLuca; Glenville Jones; Craig F Munns; John P Bilezikian; Andrea Giustina; Neil Binkley
Journal:  Br J Clin Pharmacol       Date:  2018-07-17       Impact factor: 4.335

Review 3.  Analytical considerations for the biochemical assessment of vitamin D status.

Authors:  Lewis Couchman; Cajetan F Moniz
Journal:  Ther Adv Musculoskelet Dis       Date:  2017-02-13       Impact factor: 5.346

4.  Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 1 liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays - impact of 3-epi-25-hydroxyvitamin D3 on assay performance.

Authors:  Stephen A Wise; Johanna E Camara; Carolyn Q Burdette; Grace Hahm; Federica Nalin; Adam J Kuszak; Joyce Merkel; Ramón A Durazo-Arvizu; Emma L Williams; Andrew N Hoofnagle; Fiona Ivison; Ralf Fischer; Jody M W van den Ouweland; Chung S Ho; Emmett W K Law; Jean-Nicolas Simard; Renaud Gonthier; Brett Holmquist; Sarah Meadows; Lorna Cox; Kimberly Robyak; Michael H Creer; Robert Fitzgerald; Michael W Clarke; Norma Breen; Pierre Lukas; Étienne Cavalier; Christopher T Sempos
Journal:  Anal Bioanal Chem       Date:  2021-08-25       Impact factor: 4.142

5.  Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) Intercomparison Study 2 - Part 2 ligand binding assays - impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance.

Authors:  Stephen A Wise; Johanna E Camara; Carolyn Q Burdette; Grace Hahm; Federica Nalin; Adam J Kuszak; Joyce Merkel; Ramón A Durazo-Arvizu; Emma L Williams; Christian Popp; Christian Beckert; Jan Schultess; Glen Van Slooten; Carole Tourneur; Camille Pease; Ravi Kaul; Alfredo Villarreal; Marcelo Cidade Batista; Heather Pham; Alex Bennett; Eugene Jansen; Dilshad Ahmed Khan; Mark Kilbane; Patrick J Twomey; James Freeman; Neil Parker; Sohail Mushtaq; Christine Simpson; Pierre Lukas; Étienne Cavalier; Christopher T Sempos
Journal:  Anal Bioanal Chem       Date:  2021-08-25       Impact factor: 4.142

6.  Assessment of serum total 25-hydroxyvitamin D assays for Vitamin D External Quality Assessment Scheme (DEQAS) materials distributed at ambient and frozen conditions.

Authors:  Christopher T Sempos; Emma L Williams; Graham D Carter; Julia Jones; Johanna E Camara; Carolyn Q Burdette; Grace Hahm; Federica Nalin; David L Duewer; Adam J Kuszak; Joyce Merkel; Andrew N Hoofnagle; Pierre Lukas; Étienne Cavalier; Ramón A Durazo-Arvizu; Peter M Crump; Christian Popp; Christian Beckert; Jan Schultess; Glen Van Slooten; Carole Tourneur; Camille Pease; Ravi Kaul; Alfredo Villarreal; Fiona Ivison; Ralf Fischer; Jody M W van den Ouweland; Chung S Ho; Emmett W K Law; Jean-Nicolas Simard; Renaud Gonthier; Brett Holmquist; Marcelo Cidade Batista; Sarah Meadows; Lorna Cox; Eugene Jansen; Dilshad Ahmed Khan; Kimberly Robyak; Michael H Creer; Mark Kilbane; Patrick J Twomey; James Freeman; Neil Parker; Jinyun Yuan; Robert Fitzgerald; Sohail Mushtaq; Michael W Clarke; Norma Breen; Christine Simpson; Stephen A Wise
Journal:  Anal Bioanal Chem       Date:  2021-11-09       Impact factor: 4.142

7.  Recalibration of 24,25-Dihydroxyvitamin D3 Results Based on NIST Standard Reference Material 972a.

Authors:  Andrew N Hoofnagle; Thomas J Laha; Ian H de Boer
Journal:  Am J Kidney Dis       Date:  2016-05       Impact factor: 8.860

Review 8.  Vitamin D testing: advantages and limits of the current assays.

Authors:  Barbara Altieri; Etienne Cavalier; Harjit Pal Bhattoa; Faustino R Pérez-López; María T López-Baena; Gonzalo R Pérez-Roncero; Peter Chedraui; Cedric Annweiler; Silvia Della Casa; Sieglinde Zelzer; Markus Herrmann; Antongiulio Faggiano; Annamaria Colao; Michael F Holick
Journal:  Eur J Clin Nutr       Date:  2020-01-06       Impact factor: 4.016

9.  From urban dust and marine sediment to Ginkgo biloba and human serum-a top ten list of Standard Reference Materials (SRMs).

Authors:  Stephen A Wise
Journal:  Anal Bioanal Chem       Date:  2021-07-21       Impact factor: 4.142

Review 10.  Vitamin D: Current Challenges between the Laboratory and Clinical Practice.

Authors:  Ludmila Máčová; Marie Bičíková
Journal:  Nutrients       Date:  2021-05-21       Impact factor: 5.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.