Literature DB >> 26168972

Personalized monitoring of therapeutic salicylic acid in dried blood spots using a three-layer setup and desorption electrospray ionization mass spectrometry.

Markus Siebenhaar1, Kai Küllmer, Nuno Miguel de Barros Fernandes, Volker Hüllen, Carsten Hopf.   

Abstract

Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26168972     DOI: 10.1007/s00216-015-8887-8

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  5 in total

1.  Ambient ionization and miniature mass spectrometry system for chemical and biological analysis.

Authors:  Xiaoxiao Ma; Zheng Ouyang
Journal:  Trends Analyt Chem       Date:  2016-12       Impact factor: 12.296

Review 2.  Direct sampling mass spectrometry for clinical analysis.

Authors:  Fan Pu; Spencer Chiang; Wenpeng Zhang; Zheng Ouyang
Journal:  Analyst       Date:  2019-02-11       Impact factor: 4.616

3.  In-capillary microextraction for direct mass spectrometry analysis of biological samples.

Authors:  Yue Ren; Wenpeng Zhang; Ziqing Lin; Lane R Bushman; Peter L Anderson; Zheng Ouyang
Journal:  Talanta       Date:  2018-07-11       Impact factor: 6.057

Review 4.  Ambient Ionization and Miniature Mass Spectrometry Systems for Disease Diagnosis and Therapeutic Monitoring.

Authors:  Wenpeng Zhang; Xiao Wang; Yu Xia; Zheng Ouyang
Journal:  Theranostics       Date:  2017-07-20       Impact factor: 11.556

Review 5.  Little to Give, Much to Gain-What Can You Do With a Dried Blood Spot?

Authors:  Bryttany McClendon-Weary; Diane L Putnick; Sonia Robinson; Edwina Yeung
Journal:  Curr Environ Health Rep       Date:  2020-09
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.