Chih-Yi Liu1, Zheng-Yao Huang. 1. Department of Electronic Engineering, National Kaohsiung University of Applied Sciences, No.415, Chien Kung Road, Kaohsiung, 807, Taiwan, cyliu@cc.kuas.edu.tw.
Abstract
The resistive switching characteristics of the Cu/SiO x /Pt structure (control sample) exhibited a direct correlation to humidity. The H2O vapor formed the Cu oxide at the Cu/SiO x interface, and Cu ions were injected from the Cu oxide into the SiO x layer, thus improving the resistive switching. However, the control sample demonstrated substantial switching dispersion in a vaporless environment. The Cu x O layer in the Cu/Cu x O/SiO x /Pt structure (Cu x O sample) helped the dissolution of Cu ions from the Cu electrode into the SiO x layer, enabling effective electrochemical resistive switching in a vaporless environment. The Cu x O sample exhibited low switching dispersion and favorable endurance characteristics in a vaporless environment.
The resistive switching characteristics of the Cu/SiO x /Pt structure (control sample) exhibited a direct correlation to humidity. The H2O vapor formed the Cu oxide at the Cu/SiO x interface, and Cu ions were injected from the Cu oxide into the SiO x layer, thus improving the resistive switching. However, the control sample demonstrated substantial switching dispersion in a vaporless environment. The Cu x O layer in the Cu/Cu x O/SiO x /Pt structure (Cu x O sample) helped the dissolution of Cu ions from the Cu electrode into the SiO x layer, enabling effective electrochemical resistive switching in a vaporless environment. The Cu x O sample exhibited low switching dispersion and favorable endurance characteristics in a vaporless environment.
Recently, resistive random access memory (RRAM) has attracted considerable interest because of its non-volatile resistance change in simple metal/insulator/metal structures [1, 2]. Depending on the material group [3], device structure [4, 5], and defect status [6, 7], various switching behaviors can be observed. The switching mechanisms are typically classified as either a valence change effect [8], a thermochemical effect [2, 9], or an electrochemical effect [10, 11], whereby distinct surface effects can be attributed to various mechanisms [12, 13]. Ke et al. proposed that the oxygen concentration influences the redox reaction in ZnO resistive switching [12], and Tsuruoka et al. suggested that H2O vapor plays as an essential role in the redox reaction of an electrochemical Cu/SiO2/Pt device [13, 14]. The effects of moisture on Cu/SiO2/Pt and Cu/Ta2O5/Pt devices were different due to different adsorption coefficients of water. H2O vapor formed a Cu oxide interface between the Cu electrode and the oxide layer after the forming process and also enhanced Cu migration within the oxide layer. The H2O vapor facilitates in the dissolution of Cu ions into the SiO2 layer, enabling effective resistive switching. The Cu/SiO2/Pt device does not perform the resistive switching without H2O vapor [13, 14]. However, there is no H2O vapor within a packaged chip, and this is a serious concern, because these devices are used in memory applications.In this study, a CuO layer was inserted between the Cu and SiO layer to improve the electrochemical resistive switching and minimize switching dispersion in a vaporless environment.
Methods
A 20-nm-thick SiO layer was deposited on a Pt-coated substrate (Pt/Ti/SiO2/Si) using radio frequency sputtering at room temperature. Subsequently, a 200-nm-thick Cu electrode was deposited using a thermal evaporator at room temperature, to form the final Cu/SiO/Pt structure (control sample). The device area was 5 × 10−5 cm2. To create the Cu/CuO/SiO/Pt structure (CuO sample), an additional 1-nm CuO layer was deposited on the SiO layer by using a thermal evaporator at room temperature. The structures of the control sample and the CuO sample are illustrated in Fig. 1, respectively. X-ray photoelectron spectroscopy (XPS; PHI-5000, ULVAC-PHI) was used to analyze the composition of the CuO layer. The electrical measurements were performed using an HP 4155B semiconductor parameter analyzer, and the measurements were taken in both air (60 % relative humidity) and N2 environments at room temperature. The bias voltage was applied on the top electrode while the bottom electrode was grounded.
Fig. 1
Illustrations of the sample structures. a the control sample and b the CuO sample
Illustrations of the sample structures. a the control sample and b the CuO sample
Results and Discussion
Figure 2 depicts the XPS Cu 2p3/2 spectra of the CuO layer. The detailed chemical structure information was extracted through deconvolution of Cu 2p3/2 peaks, which showed a CuO peak locating at 934 eV and a Cu2O peak locating at 932.6 eV. The CuO layer is the mixture of CuO and Cu2O. Figure 3 shows the resistive switching characteristics of the control and the CuO samples in both air and N2 environments. A positive-forming voltage was used to initialize the resistive switching; the resistance state was then switched from an initial resistance state (IRS) to a low resistance state (LRS). Following this transition, a negative Reset voltage was applied to switch from the LRS to a high resistance state (HRS). Subsequently, using a positive Set voltage, the HRS was switched back to a LRS. The device resistance can be reversibly switched between a LRS and a HRS by a Set voltage and a Reset voltage. Figure 3c, d illustrates the resistive switching characteristics of the CuO sample in air and N2 environments, and the behaviors were similar to those of the control sample in air. According to our previous study [15], device structure, and switching behavior, the resistive switchings of the control sample in air and the CuO sample in both environments are dominated by the electrochemical model with a Cu conducting filament. However, as shown in Fig. 3b, the control sample in the N2 environment required substantially higher operating voltages. The control sample in the N2 environment also showed a reversible unipolar switching, and the temperature coefficient of LRS resistance was negative. Therefore, the switching mechanism should be the thermochemical effect with conducting filaments of oxygen-related defects.
Fig. 2
XPS of the CuO layer. Cu 2p3/2 XPS spectra of the CuO layer
Fig. 3
The resistive switching characteristics in different measurement environments. a The control sample in air. b The control sample in N2. c The CuO sample in air. d The CuO sample in N2
XPS of the CuO layer. Cu 2p3/2 XPS spectra of the CuO layerThe resistive switching characteristics in different measurement environments. a The control sample in air. b The control sample in N2. c The CuO sample in air. d The CuO sample in N2Tsuruoka et al. proposed that a Cu/SiO2/Pt structure exhibits no resistive switching in a vacuum or N2 environment (no H2O vapor) because of the desorption of residual water from the SiO2 layer [13]. Because the composition of the SiO film influences the switching mechanism [16], the result of this study in N2 differed from the result of Tsuruoka et al., which may be due to the dissimilar composition between SiO and SiO2 layers. Although there was some difference between Tsuruoka’s study and our control sample in N2, these two samples both performed unfavorably because of a lack of humidity and exhibited no electrochemical resistive switching. Because no copper oxide was formed at the Cu/SiO (or SiO2) interface of these two samples, no electrochemical resistive switching was observed. The Cu ion concentrations were calculated using the cyclic voltammetry (CV) method [17], and the results are presented in Fig. 4. The CV method is used to study the redox reaction of Cu within the device. The applied voltage swept to 0.15 V and then swept back until the current was zero. During this sweeping period, oxidized Cu ions were injected into the SiO thin film. The amount of Cu ions (Q) can be calculated, and then, Cu ion concentration (Cion) can be determined by the formula , where N is Avogadro’s number and V is the device volume. The CuO sample contained higher Cu ion concentrations than those in the control samples. In addition, the two samples contained larger Cu ion concentrations in air than in N2. Tsuruoka et al. proposed that H2O molecules would form a hydrogen-bond network at grain boundaries in SiO2 [13] and thus had larger Cu ion concentration. Therefore, the humidity and CuO layer both help the dissolution of Cu ions into SiO layer. The electrochemical resistive switching has three rate-limiting processes [13]: the Cu ionization at the Cu/SiO interface, the migration of Cu ions in the SiO film, and the nucleation of Cu at the Pt bottom electrode. In this study, the Cu nucleation at Pt electrode would not the rate-limiting process. The control sample in N2 had the lowest Cu ion concentrations, and it cannot show an electrochemical resistive switching, which means that the Cu ionization at the Cu/SiO interface is the rate-limiting process in N2. Willis and Lang [18] proposed the three possible mechanisms for the Cu ionization at the Cu/SiO2 interface under a positive applied voltage: the anodization-like process that Cu atoms are injected directly into the SiO2 layer by the dissolution reaction Cu → Cu + ze−, Cu ions injected into the SiO2 from the CuO formed at the Cu/SiO2 interface due to reduction of the SiO2, and the chemical oxidation of Cu atoms at the Cu/SiO2 interface via H2O, O2, or out-gassing of the oxide [13]. In this study, the Cu/SiO/Pt cannot electrochemically switch in N2. Therefore, the former two mechanisms should be excluded.
Fig. 4
Influence of the measurement environment on the Cu ion concentration. The Cu ion concentrations of the control sample and the CuO sample in air and N2
Influence of the measurement environment on the Cu ion concentration. The Cu ion concentrations of the control sample and the CuO sample in air and N2Figure 5a–c depicts the operating voltages of the two samples in both environments. The control sample in N2 exhibited the highest operating voltages because of the lowest Cu ion concentration within the SiO layer. Both samples exhibited lower operating voltages in air, as the H2O vapor increased the Cu ion concentration in the SiO layer. Tappertzhofen et al. proposed that there was no copper oxide at Cu/SiO2 interface before the forming process, but the copper oxide was found after the forming process in air [14]. In addition, this electrochemical oxidation was not observed in anhydrous atmosphere. We also fabricated a Ni (200 nm)/CuO (1 nm)/SiO (20 nm)/Pt structure (not shown) which did not have an electrochemical resistive switching. This means that the 1-nm CuO interlayer did not provide enough Cu ions to form Cu conducting filaments. Since the Cu electrode cannot be directly ionized to be Cu ions and a 1-nm CuO interlayer does not provide enough Cu ions to form Cu conducting filaments, the possible explanation is that the Cumetal is transformed into immediate states of Cu oxide via the CuO layer and then Cu ions can be injected from these immediate states by a positive electric field. Since the copper oxide cannot be electrochemically formed without a moisture environment, a CuO layer in this study was deposited between the Cu and SiO layers to solve this issue. The deposited CuO layer also can help the dissolution of Cu ions from the Cu electrode into the SiO layer, thus increasing the Cu ion concentration in the SiO layer. This increase in the Cu ion concentration effectively reduced the forming and Set voltages. Figure 5d–f shows the device resistances in both air and N2. The LRS conduction of the two samples in air and N2 exhibited ohmic behavior. The LRS resistances were approximately determined according to the current compliance during the Set process. The two samples exhibited lower LRS resistances in air, which may be due to an increased Cu ion concentration in the SiO layer during the Set process [8]. This increased concentration of Cu ions caused a formation of wider conduction filaments. The IRS and HRS conductions of the two samples were dominated by the Schottky emission (not shown). The two samples exhibited lower IRS resistances in air because of a lower Schottky barrier height. All switching parameters of the CuO sample had larger variation in N2 than in air. H2O molecules would form a hydrogen-bond network at grain boundaries in SiO2 [13] and thus enhanced Cu migration in the SiO layer. Therefore, the CuO sample had larger Cu ion concentration in air than in N2. The supply of Cu ions influenced the operating voltages and the stability to grow Cu conducting filaments. Hence, the CuO sample had a lower Cu ion concentration in N2 and thus had larger variation in switching parameters.
Fig. 5
The parameters of resistive switching of the two samples. a The forming voltage. b The Set voltage. c The Reset voltage. d The IRS voltage. e The LRS resistance. f The HRS resistance
The parameters of resistive switching of the two samples. a The forming voltage. b The Set voltage. c The Reset voltage. d The IRS voltage. e The LRS resistance. f The HRS resistanceFigure 6 shows the endurance characteristics of the two samples in both environments. The control sample in N2 exhibited the least favorable endurance characteristics, because of its non-optimized thermochemical switching. Both of the samples exhibited a more favorable endurance in air than in N2, which indicated that H2O vapor increased the Cu ion concentration and thus improved the resistive switching. In a packaged chip, the RRAM device must switch in an environment without H2O vapor. The CuO sample demonstrated favorable endurance for more than 2000 cycles in the N2 environment, demonstrating that it is suitable for RRAM applications.
Fig. 6
Endurance characteristics in different measurement environments. a The control sample in air. b The control sample in N2. c The CuO sample in air. d The CuO sample in N2
Endurance characteristics in different measurement environments. a The control sample in air. b The control sample in N2. c The CuO sample in air. d The CuO sample in N2
Conclusions
This study investigated the addition of a CuO layer to a Cu/SiO/Pt structure for maintaining the electrochemical resistive switching capabilities in a vaporless environment. The Cu ionization at the Cu/SiO interface is the rate-limiting process for the electrochemical resistive switching in N2. Therefore, Cu/SiO/Pt cannot have an electrochemical resistive switching in N2. Therefore, in the Cu/CuO/SiO/Pt structure, the CuO layer helped the dissolution of Cu ions from the Cu electrode into the SiO layer, effectively minimizing the switching dispersion. The Cu/CuO/SiO/Pt also exhibited favorable endurance characteristics in a vaporless environment, demonstrating that it is suitable for practical applications.