Urethral complications after tension-free vaginal tape procedures: A surgical management case series.

Fotios Sergouniotis1, Björn Jarlshammar1, Per-Göran Larsson1.   

Abstract

AIM: To analyze the clinical features, diagnostic modalities, and the surgical management of urethral complications after tension-free vaginal tape procedures.
METHODS: This study encompasses a retrospective review of nine patients presented with urethral complications after midurethral sling procedures. The patients underwent the procedures during a period from 1999 to 2012 in three different regional hospitals in the southwest part of Sweden. The time from sling placement to diagnosis, the risk factors, clinical features, diagnosis, surgical management, and functional outcome are presented. The presenting symptoms were described as either early onset (< 12 mo) or late onset (> 12 mo) according to when they were first reported.
RESULTS: Eight cases of urethral erosion and one case of bladder-neck erosion were detected. The mean interval for diagnoses of the erosions ranged from 3 mo to 11 years. The most common presenting symptoms included de novo urgency with or without incontinence (7/9 patients), urinary retention/voiding dysfunction (4/9 patients), urethritis (4/9 patients), relapse of stress-incontinence (3/9 patients), recurrent urinary tract infections (5/9 patients), and hematuria (1/9 patient). In most cases, voiding dysfunction and urethritis occurred early after the operation. The surgical management applied in most cases was transurethral resection of the intraurethral part of the mesh. The removal of the intraurethral mesh resulted in improvement or complete cure of urgency symptoms in 5/7 patients with urgency. Four patients were reoperated with a new stress-incontinence surgery, one with laparoscopic Burch, and three with retropubic tension-free vaginal tape procedures.
CONCLUSION: Urethral complications should be suspected in the case of de novo urgency and relapse of stress-incontinence. Transurethral excision of the intraurethral mesh is the recommended treatment.

Entities:  

Keywords:  Bladder neck erosion; Complications; Intraurethral mesh; Stress incontinence; Tension-free vaginal tape; Urethral erosion

Year:  2015        PMID: 26167464      PMCID: PMC4491931          DOI: 10.5527/wjn.v4.i3.396

Source DB:  PubMed          Journal:  World J Nephrol        ISSN: 2220-6124


  27 in total

1.  The standardisation of terminology of lower urinary tract function: report from the Standardisation Sub-committee of the International Continence Society.

Authors:  Paul Abrams; Linda Cardozo; Magnus Fall; Derek Griffiths; Peter Rosier; Ulf Ulmsten; Philip van Kerrebroeck; Arne Victor; Alan Wein
Journal:  Am J Obstet Gynecol       Date:  2002-07       Impact factor: 8.661

Review 2.  A review of the tension-free vaginal tape procedure: outcomes, complications, and theories.

Authors:  M M Brophy; J J Klutke; C G Klutke
Journal:  Curr Urol Rep       Date:  2001-10       Impact factor: 3.092

Review 3.  [Urinary complications in sub-urethral sling procedures].

Authors:  X Deffieux; K Bonnet; N Chevalier; A Gervaise; R Frydman; H Fernandez
Journal:  J Gynecol Obstet Biol Reprod (Paris)       Date:  2005-12

4.  Presentation and management of major complications of midurethral slings: Are complications under-reported?

Authors:  Donna Y Deng; Matthew Rutman; Shlomo Raz; Larissa V Rodriguez
Journal:  Neurourol Urodyn       Date:  2007       Impact factor: 2.696

Review 5.  TVT-Secur mini-sling for stress urinary incontinence: a review of outcomes at 12 months.

Authors:  Colin A Walsh
Journal:  BJU Int       Date:  2011-07-14       Impact factor: 5.588

6.  Urinary tract erosions after synthetic pubovaginal slings: diagnosis and management strategy.

Authors:  J Q Clemens; J O DeLancey; G J Faerber; O L Westney; E J Mcguire
Journal:  Urology       Date:  2000-10-01       Impact factor: 2.649

7.  Polypropylene mesh tape for stress urinary incontinence: complications of urethral erosion and outlet obstruction.

Authors:  Susan D Sweat; Nancy B Itano; J Quentin Clemens; Wade Bushman; Jennifer Gruenenfelder; Edward J McGuire; Deborah J Lightner
Journal:  J Urol       Date:  2002-07       Impact factor: 7.450

Review 8.  Urethral injury associated with minimally invasive mid-urethral sling procedures for the treatment of stress urinary incontinence: a case series and systematic literature search.

Authors:  H C Morton; P Hilton
Journal:  BJOG       Date:  2009-05-11       Impact factor: 6.531

9.  Complications of synthetic slings used in female stress urinary incontinence and applicability of the new IUGA-ICS classification.

Authors:  Eckhard Petri; Kiran Ashok
Journal:  Eur J Obstet Gynecol Reprod Biol       Date:  2012-09-01       Impact factor: 2.435

10.  Novel surgical technique for the treatment of female stress urinary incontinence: transobturator vaginal tape inside-out.

Authors:  Jean de Leval
Journal:  Eur Urol       Date:  2003-12       Impact factor: 20.096

View more
  2 in total

1.  Functional outcomes of vaginal surgery for urethral extrusion of mid-urethral tape in women.

Authors:  Bogdan Toia; Stephen Unterberg; Neha Sihra; Mahreen Pakzad; Rizwan Hamid; Jeremy L Ockrim; Tamsin J Greenwell
Journal:  Int Urogynecol J       Date:  2021-04-06       Impact factor: 1.932

2.  Road to recovery after transvaginal surgery for urethral mesh perforation: evaluation of outcomes and subsequent procedures.

Authors:  Casey G Kowalik; Joshua A Cohn; Andrea Kakos; Patrick Lang; W Stuart Reynolds; Melissa R Kaufman; Mickey M Karram; Roger R Dmochowski
Journal:  Int Urogynecol J       Date:  2018-01-29       Impact factor: 2.894

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.