Literature DB >> 26165301

Voltammetric Detection of Oxalic Acid by Using Glassy Carbon Electrodes with Covalently Attached Nitrogen-containing Functional Groups.

Hiroaki Matsuura1, Syuhei Akabe, Tsubasa Kitamura, Takuto Takahashi, Shunichi Uchiyama.   

Abstract

We report on a novel voltammetric detection of oxalic acid by using glassy carbon electrodes with covalently attached nitrogen-containing functional groups prepared by stepwise electrolysis. A glassy carbon electrode electrooxidized in an ammonium carbamate solution was electroreduced at -1.0 V (vs. Ag/AgCl) in 1.0 M sulfuric acid for a long time. We found that the electrocatalytic oxidation wave of oxalic acid obtained by this modified glassy carbon electrode was moved to a more negative potential region than that obtained by a platinum electrode in an acidic medium. A good linearity for the peak current signals was observed in the concentration range from 0.1 to 50 mM.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26165301     DOI: 10.2116/analsci.31.733

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  1 in total

1.  Graphitic carbon nitride (g-C3N4)/graphite nanocomposite as an extraordinarily sensitive sensor for sub-micromolar detection of oxalic acid in biological samples.

Authors:  Taher Alizadeh; Sahar Nayeri; Negin Hamidi
Journal:  RSC Adv       Date:  2019-04-29       Impact factor: 3.361

  1 in total