Literature DB >> 26165217

Biomechanical Analysis of Cervical Disc Replacement and Fusion Using Single Level, Two Level, and Hybrid Constructs.

Anup A Gandhi1, Swathi Kode, Nicole A DeVries, Nicole M Grosland, Joseph D Smucker, Douglas C Fredericks.   

Abstract

STUDY
DESIGN: A biomechanical study comparing arthroplasty with fusion using human cadaveric C2-T1 spines.
OBJECTIVE: To compare the kinematics of the cervical spine after arthroplasty and fusion using single level, 2 level and hybrid constructs. SUMMARY OF BACKGROUND DATA: Previous studies have shown that spinal levels adjacent to a fusion experience increased motion and higher stress which may lead to adjacent segment disc degeneration. Cervical arthroplasty achieves similar decompression but preserves the motion at the operated level, potentially decreasing the occurrence of adjacent segment disc degeneration.
METHODS: 11 specimens (C2-T1) were divided into 2 groups (BRYAN and PRESTIGE LP). The specimens were tested in the following order; intact, single level total disc replacement (TDR) at C5-C6, 2-level TDR at C5-C6-C7, fusion at C5-C6 and TDR at C6-C7 (Hybrid construct), and lastly a 2-level fusion. The intact specimens were tested up to a moment of 2.0 Nm. After each surgical intervention, the specimens were loaded until the primary motion (C2-T1) matched the motion of the respective intact state (hybrid control).
RESULTS: An arthroplasty preserved motion at the implanted level and maintained normal motion at the nonoperative levels. Arthrodesis resulted in a significant decrease in motion at the fused level and an increase in motion at the unfused levels. In the hybrid construct, the TDR adjacent to fusion preserved motion at the arthroplasty level, thereby reducing the demand on the other levels.
CONCLUSION: Cervical disc arthroplasty with both the BRYAN and PRESTIGE LP discs not only preserved the motion at the operated level, but also maintained the normal motion at the adjacent levels. Under simulated physiologic loading, the motion patterns of the spine with the BRYAN or PRESTIGE LP disc were very similar and were closer than fusion to the intact motion pattern. An adjacent segment disc replacement is biomechanically favorable to a fusion in the presence of a pre-existing fusion.

Entities:  

Mesh:

Year:  2015        PMID: 26165217     DOI: 10.1097/BRS.0000000000001044

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  22 in total

1.  Finite element model predicts the biomechanical performance of cervical disc replacement and fusion hybrid surgery with various geometry of ball-and-socket artificial disc.

Authors:  Yang Li; Guy R Fogel; Zhenhua Liao; Weiqiang Liu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-08       Impact factor: 2.924

Review 2.  Cervical disc replacement - emerging equivalency to anterior cervical discectomy and fusion.

Authors:  Aaron J Buckland; Joseph F Baker; Ryan P Roach; Jeffrey M Spivak
Journal:  Int Orthop       Date:  2016-04-08       Impact factor: 3.075

3.  Biomechanical analysis of cervical range of motion and facet contact force after a novel artificial cervical disc replacement.

Authors:  Kangkang Huang; Tingkui Wu; Beiyu Wang; Hao Liu
Journal:  Am J Transl Res       Date:  2019-10-15       Impact factor: 4.060

4.  Comparative biomechanical analyses of lower cervical spine post anterior fusion versus intervertebral disc arthroplasty: A geometrically patient-specific poroelastic finite element investigation.

Authors:  Kinda Khalaf; Mohammad Nikkhoo
Journal:  J Orthop Translat       Date:  2022-07-15       Impact factor: 4.889

5.  Biomechanical consideration of prosthesis selection in hybrid surgery for bi-level cervical disc degenerative diseases.

Authors:  Zhongjun Mo; Qi Li; Zhiwei Jia; Jiemeng Yang; Duo Wai-Chi Wong; Yubo Fan
Journal:  Eur Spine J       Date:  2016-09-21       Impact factor: 3.134

Review 6.  Mid- to Long-Term Outcomes of Cervical Disc Arthroplasty versus Anterior Cervical Discectomy and Fusion for Treatment of Symptomatic Cervical Disc Disease: A Systematic Review and Meta-Analysis of Eight Prospective Randomized Controlled Trials.

Authors:  Yan Hu; Guohua Lv; Siying Ren; Daniel Johansen
Journal:  PLoS One       Date:  2016-02-12       Impact factor: 3.240

7.  Cervical disc arthroplasty with Prestige-LP for the treatment of contiguous 2-level cervical degenerative disc disease: 5-year follow-up results.

Authors:  Xinlin Gao; Yi Yang; Hao Liu; Yang Meng; Junfeng Zeng; Tingkui Wu; Ying Hong
Journal:  Medicine (Baltimore)       Date:  2018-01       Impact factor: 1.889

8.  Discover cervical disc arthroplasty versus anterior cervical discectomy and fusion in symptomatic cervical disc diseases: A meta-analysis.

Authors:  Lei Shangguan; Guang-Zhi Ning; Yu Tang; Zhe Wang; Zhuo-Jing Luo; Yue Zhou
Journal:  PLoS One       Date:  2017-03-30       Impact factor: 3.240

9.  Long-term Evaluation of Cervical Disc Arthroplasty with the Mobi-C© Cervical Disc: A Randomized, Prospective, Multicenter Clinical Trial with Seven-Year Follow-up.

Authors:  Kris Radcliff; Reginald J Davis; Michael S Hisey; Pierce D Nunley; Gregory A Hoffman; Robert J Jackson; Hyun W Bae; Todd Albert; Dom Coric
Journal:  Int J Spine Surg       Date:  2017-11-28

Review 10.  Cervical Disc Arthroplasty: A Comprehensive Review of Single-Level, Multilevel, and Hybrid Procedures.

Authors:  Joseph L Laratta; Jamal N Shillingford; Comron Saifi; K Daniel Riew
Journal:  Global Spine J       Date:  2017-05-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.