Literature DB >> 26164561

Metal Ion Concentrations in Young, Active Patients Following Total Hip Arthroplasty with the Use of Modern Bearing Couples.

Denis Nam1, James A Keeney2, Ryan M Nunley1, Staci R Johnson1, John C Clohisy1, Robert L Barrack1.   

Abstract

The purpose of this study was to compare whole blood metal ion levels in young, active patients undergoing primary total hip arthroplasty with the use of a cobalt-alloy (ten patients), ceramic (15 patients), or oxinium (11 patients) femoral head and highly crosslinked polyethylene acetabular liner. At 2 years postoperatively, mean cobalt concentrations were 3.0 times higher in the cobalt-alloy cohort versus the ceramic cohort, and 2.3 times higher versus the oxinium cohort (P=0.3-0.5). Titanium levels were consistently elevated at all postoperative time points versus preoperatively in all cohorts. Young, active patients following THA demonstrate elevated cobalt and titanium concentrations. Use of a ceramic or oxinium femoral head decreased the degree of cobalt elevation versus a cobalt-alloy femoral head, but did not reach statistical significance.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  ceramic; cobalt; metal ions; oxinium; total hip arthroplasty

Mesh:

Substances:

Year:  2015        PMID: 26164561     DOI: 10.1016/j.arth.2015.06.025

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  4 in total

1.  Effect of Femoral Stem Modular Neck's Material on Metal Ion Release.

Authors:  Janie Barry; Marc-Olivier Kiss; Vincent Massé; Martin Lavigne; Jihad Matta; Pascal-Andre Vendittoli
Journal:  Open Orthop J       Date:  2017-11-29

2.  Corrosion and adverse local tissue reaction after total hip arthroplasty with a modular titanium alloy femoral neck.

Authors:  Colin D Canham; Pavel I Muradov; Jordan B Simpson; Stephen J Incavo
Journal:  Arthroplast Today       Date:  2017-04-15

3.  Serum cobalt concentrations remain at low levels at a minimum of 20 years following metal-on-metal total hip arthroplasty.

Authors:  Wenzel Waldstein; Ulrich Koller; Bernhard Springer; Paul Kolbitsch; Wolfram Brodner; Reinhard Windhager; Richard Lass
Journal:  Bone Joint Res       Date:  2020-05-16       Impact factor: 5.853

4.  Blood titanium levels in patients with large and sliding titanium implants.

Authors:  Martina Tognini; Harry Hothi; Stewart Tucker; Edel Broomfield; Masood Shafafy; Panos Gikas; Anna Di Laura; Johann Henckel; Alister Hart
Journal:  BMC Musculoskelet Disord       Date:  2022-08-16       Impact factor: 2.562

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.