Jun-Ming Zhu1, Rui-Dong Qi1, Yong-Min Liu1, Jun Zheng1, Xiao-Yan Xing1, Li-Zhong Sun2.   

Abstract

OBJECTIVES: The presence of an isolated left vertebral artery (ILVA) remains a challenging issue for thoracic endovascular aortic repair (TEVAR) of type B dissection if the proximal landing zones are inadequate. We retrospectively reviewed our experience of the surgical management of complicated type B dissection with an ILVA using the stented elephant trunk technique.
METHODS: Between February 2009 and May 2013, 7 patients with complicated type B dissection (acute = 2 and chronic = 5) underwent the stented elephant trunk procedure under hypothermic cardiopulmonary bypass with selective antegrade cerebral perfusion. All the patients were males with a median age of 53 ± 6 (range 42-59) years. Preoperative lower limb ischaemia was observed in 1 patient, renal dysfunction in 1 patient and visceral ischaemia in 1 patient.
RESULTS: There were no in-hospital deaths. The median ventilator support time was 16 ± 3 (range 11-20) h. Ischaemia of the lower limb and viscera was ameliorated after surgical stent-graft implantation. Continuous renal replacement therapy was not required in patients with preoperative renal dysfunction after surgery. No neurological deficits were observed in any patients prior to hospital discharge. One patient underwent TEVAR due to distal aortic dilatation within the mean follow-up period, which was 44 ± 19 months.
CONCLUSION: Repair of complicated type B dissection with an ILVA using the stented elephant trunk technique was associated with satisfactory surgical results in patients with inadequate proximal fixation zones. This technique is an alternative to TEVAR for complicated type B dissection with inadequate proximal landing zones.
© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Isolated left vertebral artery; Stented elephant trunk technique; Type B dissection

Mesh:

Year:  2015        PMID: 26164261     DOI: 10.1093/ejcts/ezv242

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  2 in total

1.  Three Rare Structural Anomalies: Right Aberrant Subclavian Artery, Kommerell's Diverticulum, and Isolated Left Vertebral Artery All Associated with Type B Aortic Dissection.

Authors:  Yasser Farag Elghoneimy; Medhat Reda Nashy; Ahmed Elsayed Mahmoud; Asayel Ali Alruwaili; Assayl Rabea Alotaibi
Journal:  Case Rep Surg       Date:  2019-03-17

Review 2.  One-stage supraclavicular hybrid procedure for type B aortic dissection involving three rare anatomical anomalies: a case report and literature review.

Authors:  Junhang Chen; Xiangchen Dai; Jiechang Zhu; Fanguo Hu; Peng Li; Yudong Luo; Hailun Fan; Zhou Feng; Yiwei Zhang
Journal:  J Int Med Res       Date:  2021-06       Impact factor: 1.671

  2 in total