Literature DB >> 26163384

FIRST EURADOS INTERCOMPARISON EXERCISE OF EYE LENS DOSEMETERS FOR MEDICAL APPLICATIONS.

I Clairand1, M Ginjaume2, F Vanhavere3, E Carinou4, J Daures5, M Denoziere5, E H Silva6, M Roig2, S Principi2, L Van Rycheghem7.   

Abstract

In the context of the decrease in the eye lens dose limit for occupational exposure to 20 mSv per year stated by the recent revision of the European Basic Safety Standards Directive 2013/59/EURATOM, the European Radiation Dosimetry Group (EURADOS) has organised in 2014, for the first time, an intercomparison exercise for eye lens dosemeters. The main objective was to assess the capabilities of the passive eye lens dosemeters currently in use in Europe for occupational monitoring in medical fields. A total of 20 European individual monitoring services from 15 different countries have participated. The dosemeters provided by the participants were all composed of thermoluminescent detectors, of various types and designs. The irradiations were carried out with several photon fields chosen to cover the energy and angle ranges encountered in medical workplace. Participants were asked to report the doses in terms of Hp(3) using their routine protocol. The results provided by each participant were compared with the reference delivered doses. All the results were anonymously analysed. Results are globally satisfactory since, among the 20 participants, 17 were able to provide 90 % of their response in accordance with the ISO 14146 standard requirements.
© The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

Entities:  

Mesh:

Year:  2015        PMID: 26163384     DOI: 10.1093/rpd/ncv368

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  Evaluation of novel X-ray protective eyewear in reducing the eye dose to interventional radiology physicians.

Authors:  Mime Endo; Yoshihiro Haga; Masahiro Sota; Akiko Tanaka; Kazuki Otomo; Yuuki Murabayashi; Mitsuya Abe; Yuji Kaga; Yohei Inaba; Msatoshi Suzuki; Taiichiro Meguro; Koichi Chida
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

2.  Occupational eye dose in interventional cardiology procedures.

Authors:  Yoshihiro Haga; Koichi Chida; Yuji Kaga; Masahiro Sota; Taiichiro Meguro; Masayuki Zuguchi
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

3.  Determination of a reliable assessment for occupational eye lens dose in nuclear medicine.

Authors:  Noriaki Miyaji; Kenta Miwa; Takashi Iimori; Kei Wagatsuma; Hiroyuki Tsushima; Noriyo Yokotsuka; Taisuke Murata; Tetsuharu Kasahara; Takashi Terauchi
Journal:  J Appl Clin Med Phys       Date:  2022-07-01       Impact factor: 2.243

4.  Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy.

Authors:  Yoshihiro Haga; Koichi Chida; Yuichiro Kimura; Shinsuke Yamanda; Masahiro Sota; Mitsuya Abe; Yuji Kaga; Taiichiro Meguro; Masayuki Zuguchi
Journal:  J Radiat Res       Date:  2020-09-08       Impact factor: 2.724

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.