Literature DB >> 26162327

Highly sensitive label free electrochemical detection of VGEF165 tumor marker based on "signal off" and "signal on" strategies using an anti-VEGF165 aptamer immobilized BSA-gold nanoclusters/ionic liquid/glassy carbon electrode.

Mojtaba Shamsipur1, Leila Farzin2, Mahmoud Amouzadeh Tabrizi3, Fatemeh Molaabasi4.   

Abstract

In this work, a label free electrochemical aptasensor for the detection of ultra-traces of vascular endothelial growth factor (VEGF165) based on "signal off" and "signal on" mechanisms of response was developed. The BSA-gold nanoclusters/ionic liquid (BSA-AuNCs/IL) was used as a suitable nanocomposite platform for immobilization of the aptamer on a glassy carbon electrode. In "signal off" mechanism, the interaction of VEGF165 with its anti-VEGF165 aptamers, resulted in desorption of methylene blue (MB) probe from aptamer and its release into solution. Consequently, the decrease in current intensity of the differential pulse voltammogram of adsorbed MB was monitored and found to be linearly proportional with increasing concentration of VEGF165 in sample solution in the range of 1-120 pM with a limit of detection of 0.32p M. While, in "signal on" mechanism, the interaction of immobilized anti-VEGF165 aptamers on the electrode surface with VEGF165, led to more mass-transfer limiting of the [Fe(CN)6](3-/4-) probe to the electrode surface. Therefore, the charge transfer resistance (Rct) of the probe was increased linearly with increasing concentration of VEGF165 in the range of 2.5-250 pM with a limit of detection of 0.48 pM. The experimental results demonstrated that both of these mechanisms are suitable for determination of low levels of the VEGF165 tumor marker in serum samples.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  BSA-nananoclusters; Differential pulse voltammetry; Electrochemical aptasensor; Impedimetry; VEGF(165)

Mesh:

Substances:

Year:  2015        PMID: 26162327     DOI: 10.1016/j.bios.2015.06.079

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  13 in total

1.  Photoelectrochemical aptamer-based sensing of the vascular endothelial growth factor by adjusting the light harvesting efficiency of g-C3N4 via porous carbon spheres.

Authors:  Ya-Ling Liu; Hui-Mei Da; Ya-Qin Chai; Ruo Yuan; Hong-Yan Liu
Journal:  Mikrochim Acta       Date:  2019-04-10       Impact factor: 5.833

2.  An electrochemical aptamer-based assay for femtomolar determination of insulin using a screen printed electrode modified with mesoporous carbon and 1,3,6,8-pyrenetetrasulfonate.

Authors:  Mahmoud Amouzadeh Tabrizi; Mojtaba Shamsipur; Reza Saber; Saeed Sarkar; Maryam Besharati
Journal:  Mikrochim Acta       Date:  2017-12-18       Impact factor: 5.833

3.  Signalling probe displacement electrochemical aptasensor for malignant cell surface nucleolin as a breast cancer biomarker based on gold nanoparticle decorated hydroxyapatite nanorods and silver nanoparticle labels.

Authors:  Leila Farzin; Mojtaba Shamsipur; Leila Samandari; Shahab Sheibani
Journal:  Mikrochim Acta       Date:  2018-02-03       Impact factor: 5.833

Review 4.  From Small Molecules Toward Whole Cells Detection: Application of Electrochemical Aptasensors in Modern Medical Diagnostics.

Authors:  Robert Ziółkowski; Marta Jarczewska; Łukasz Górski; Elżbieta Malinowska
Journal:  Sensors (Basel)       Date:  2021-01-21       Impact factor: 3.576

5.  Graphite nanocrystals coated paper-based electrode for detection of SARS-Cov-2 gene using DNA-functionalized Au@carbon dot core-shell nanoparticles.

Authors:  Mohammad Ali Farzin; Hassan Abdoos; Reza Saber
Journal:  Microchem J       Date:  2022-05-11       Impact factor: 5.304

6.  One Step Assembly of Thin Films of Carbon Nanotubes on Screen Printed Interface for Electrochemical Aptasensing of Breast Cancer Biomarker.

Authors:  Muhammad Azhar Hayat Nawaz; Sajid Rauf; Gaelle Catanante; Mian Hasnain Nawaz; Gilvanda Nunes; Jean Louis Marty; Akhtar Hayat
Journal:  Sensors (Basel)       Date:  2016-10-06       Impact factor: 3.576

Review 7.  Electrochemical, Electrochemiluminescence, and Photoelectrochemical Aptamer-Based Nanostructured Sensors for Biomarker Analysis.

Authors:  Andrea Ravalli; Diego Voccia; Ilaria Palchetti; Giovanna Marrazza
Journal:  Biosensors (Basel)       Date:  2016-08-02

Review 8.  Current Advances in Aptamers for Cancer Diagnosis and Therapy.

Authors:  Shin-Ichiro Hori; Alberto Herrera; John J Rossi; Jiehua Zhou
Journal:  Cancers (Basel)       Date:  2018-01-03       Impact factor: 6.639

9.  Shape-Controlled Synthesis of Luminescent Hemoglobin Capped Hollow Porous Platinum Nanoclusters and their Application to Catalytic Oxygen Reduction and Cancer Imaging.

Authors:  Fatemeh Molaabasi; Morteza Sarparast; Mojtaba Shamsipur; Leila Irannejad; Ali Akbar Moosavi-Movahedi; Abouzar Ravandi; Behnam Hajipour Verdom; Reza Ghazfar
Journal:  Sci Rep       Date:  2018-09-28       Impact factor: 4.379

10.  Impedimetric Biosensors for Detecting Vascular Endothelial Growth Factor (VEGF) Based on Poly(3,4-ethylene dioxythiophene) (PEDOT)/Gold Nanoparticle (Au NP) Composites.

Authors:  Minsoo Kim; Raymond Iezzi; Bong Sup Shim; David C Martin
Journal:  Front Chem       Date:  2019-04-16       Impact factor: 5.221

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.