Literature DB >> 26161766

Isolating Suture Slippage During Cadaveric Testing of Knotless Anchors.

Stephen A Klinge1, Bryan G Vopat, David Paller, Anthony L Avery, Sarath Koruprolu, Paul D Fadale.   

Abstract

We evaluated a testing method designed to isolate and analyze the effectiveness of different suture-retention mechanisms in knotless suture anchors used for rotator cuff repairs. Six knotless PushLock implants (Arthrex) with a suture-retention mechanism dependent on a press-fit of suture between the anchor's outer diameter and surrounding bone were compared with 6 ReelX STT devices (Stryker) reliant on an intrinsic suture-locking mechanism. Suture slippage beyond minimal clinical failure thresholds, as well as ultimate failure load, were determined with a novel testing fixture that isolated suture slippage. Suture slippage was isolated from anchor-bone disengagement. Each PushLock exhibited suture slippage of more than 3 mm, and each ReelX exhibited slippage of less than 3 mm. The PushLock implants also exhibited significantly (P < .05) more interval and maximum slippage; 5 of these 6 implants failed via complete suture slippage before dynamic testing could be completed. All ReelX devices survived dynamic testing and ultimately failed via suture breakage. This novel axial load biomechanical testing technique isolated suture slippage in 2 uniquely designed knotless anchors. The press-fit PushLock implant was prone to slippage failure, whereas the ReelX device with its internal suture-locking mechanism exhibited minimal slippage.

Entities:  

Mesh:

Year:  2015        PMID: 26161766

Source DB:  PubMed          Journal:  Am J Orthop (Belle Mead NJ)        ISSN: 1078-4519


  4 in total

1.  Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

Authors:  Mohammad Reza Hayeri; Daniel T Keefe; Eric Y Chang
Journal:  Skeletal Radiol       Date:  2016-01-06       Impact factor: 2.199

2.  Biomechanical comparison of four tibial fixation techniques for meniscal root sutures in posterior medial meniscus root repair: A porcine study.

Authors:  Shen-Han Wu; Tsu-Te Yeh; Wei-Chun Hsu; Alexander T H Wu; Guoan Li; Chih-Hwa Chen; Chian-Her Lee; Jia-Lin Wu
Journal:  J Orthop Translat       Date:  2020-02-17       Impact factor: 5.191

3.  Suture Slippage After Arthroscopic Cuff Repair: Medial Displacement of Suture Knots on Follow-up Ultrasonography.

Authors:  Hyungsuk Kim; Sung Bin Han; Hyun Seok Song
Journal:  Orthop J Sports Med       Date:  2021-08-13

4.  Comparison of Biomechanical Failure Loads Between Tape-Type and Conventional Sutures in Internal Knotless Anchor-Based Constructs.

Authors:  Hao-Chun Chuang; Joe-Zhi Yen; Chih-Kai Hong; Kai-Lan Hsu; Fa-Chuan Kuan; Yueh Chen; Hao-Ming Chang; Wei-Ren Su
Journal:  Orthop J Sports Med       Date:  2022-03-24
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.