Literature DB >> 2616145

Keratography as a guide to selective suture removal for the reduction of astigmatism after penetrating keratoplasty.

D J Harris1, G O Waring, L L Burk.   

Abstract

After penetrating keratoplasty in 52 eyes, keratography refraction and keratometry were used to select appropriate interrupted sutures for removal in order to reduce astigmatism. All eyes had one continuous and either 12 or 16 interrupted nylon sutures. The keratographs were examined retrospectively and separated into six groups on the basis of similar mire patterns. The removal of single sutures associated with three of these patterns reduced astigmatism by the following average amounts: symmetrical oval pattern, 0.44 diopters (D); D-shaped oval pattern, 2.07 D; and focal indentation pattern, 6.60 D. The other three patterns--mildly disrupted mires, incomplete mires, and uninterpretable mires--did not allow quantification of results. Examples of these keratographic patterns are presented and recommendations are made for their use in the management of astigmatism following penetrating keratoplasty.

Entities:  

Mesh:

Year:  1989        PMID: 2616145     DOI: 10.1016/s0161-6420(89)32679-0

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  7 in total

1.  Inadequacy of a polyester (Mersilene) suture for the reduction of astigmatism after penetrating keratoplasty.

Authors:  B A Bertram; C Drews; M Gemmill; J Guell; M Murad; G O Waring
Journal:  Trans Am Ophthalmol Soc       Date:  1990

2.  Triple procedure; analysis of outcome, refraction, and intraocular lens power calculation.

Authors:  A J Geerards; E Hassmann; W H Beekhuis; L Remeyer; G van Rij; W J Rijneveld
Journal:  Br J Ophthalmol       Date:  1997-09       Impact factor: 4.638

3.  Effect of disagreement between refractive, keratometric, and topographic determination of astigmatic axis on suture removal after penetrating keratoplasty.

Authors:  A R Sarhan; H S Dua; M Beach
Journal:  Br J Ophthalmol       Date:  2000-08       Impact factor: 4.638

4.  A comparison of two selective interrupted suture removal techniques for control of post keratoplasty astigmatism.

Authors:  R K Forster
Journal:  Trans Am Ophthalmol Soc       Date:  1997

5.  The efficacy of a single continuous nylon suture for control of post keratoplasty astigmatism.

Authors:  W Van Meter
Journal:  Trans Am Ophthalmol Soc       Date:  1996

6.  Causes of high astigmatism after penetrating keratoplasty.

Authors:  V P Hoppenreijs; G Van Rij; W H Beekhuis; W J Rijneveld; E Rinkel-van Driel
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

7.  Astigmatism after penetrating keratoplasty. Role of the suture technique.

Authors:  J N Murta; L Amaro; C Tavares; J B Mira
Journal:  Doc Ophthalmol       Date:  1994       Impact factor: 2.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.