Literature DB >> 26160597

How reliable are crystalline silica dust concentration measurements?

L A Cox1, D R Van Orden2, R J Lee3, S M Arlauckas3, R A Kautz3, A L Warzel3, K F Bailey4, A K Ranpuria5.   

Abstract

To determine how reliably commercial laboratories measure crystalline silica concentrations corresponding to OSHA's proposed limits, 105 filters were prepared with known masses of 20, 40, and 80 μg of respirable quartz corresponding to airborne silica concentrations of 25, 50, and 100 μg/m(3) and were submitted, in a blind test, to qualified commercial laboratories over a nine month period. Under these test conditions, the reported results indicated a lack of accuracy and precision needed to reliably inform regulatory compliance decisions. This was true even for filters containing only silica, without an interfering matrix. For 36 filters loaded with 20 or more micrograms of silica, the laboratories reported non-detected levels of silica. Inter-laboratory variability in this performance test program was so high that the reported results could not be used to reliably discriminate among filters prepared to reflect 8-h exposures to respirable quartz concentrations of 25, 50 and 100 μg/m(3). Moreover, even in intra-laboratory performance, there was so much variability in the reported results that 2-fold variations in exposure concentrations could not be reliably distinguished. Part of the variability and underreporting may result from the sample preparation process. The results of this study suggest that current laboratory methods and practices cannot necessarily be depended on, with high confidence, to support proposed regulatory standards with reliable data.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Crystalline silica; Interlaboratory testing; Intralaboratory testing; Precision; Variability; X-ray diffraction

Mesh:

Substances:

Year:  2015        PMID: 26160597     DOI: 10.1016/j.yrtph.2015.07.001

Source DB:  PubMed          Journal:  Regul Toxicol Pharmacol        ISSN: 0273-2300            Impact factor:   3.271


  2 in total

1.  Letter to the Editor: Preparation of respirable crystalline silica samples for subsequent analysis.

Authors:  Martin Harper; Rosa J Key-Schwartz
Journal:  Regul Toxicol Pharmacol       Date:  2016-11-05       Impact factor: 3.271

2.  Comparison of soil sampling and analytical methods for asbestos at the Sumas Mountain Asbestos Site-Working towards a toolbox for better assessment.

Authors:  Julie Wroble; Timothy Frederick; Alicia Frame; Daniel Vallero
Journal:  PLoS One       Date:  2017-07-31       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.