Literature DB >> 26160546

Optical detection enhancement in porous volumetric microfluidic capture elements using refractive index matching fluids.

M S Wiederoder1, L Peterken, A X Lu, O D Rahmanian, S R Raghavan, D L DeVoe.   

Abstract

Porous volumetric capture elements in microfluidic sensors are advantageous compared to planar capture surfaces due to higher reaction site density and decreased diffusion lengths that can reduce detection limits and total assay time. However a mismatch in refractive indices between the capture matrix and fluid within the porous interstices results in scattering of incident, reflected, or emitted light, significantly reducing the signal for optical detection. Here we demonstrate that perfusion of an index-matching fluid within a porous matrix minimizes scattering, thus enhancing optical signal by enabling the entire capture element volume to be probed. Signal enhancement is demonstrated for both fluorescence and absorbance detection, using porous polymer monoliths in a silica capillary and packed beds of glass beads within thermoplastic microchannels, respectively. Fluorescence signal was improved by a factor of 3.5× when measuring emission from a fluorescent compound attached directly to the polymer monolith, and up to 2.6× for a rapid 10 min direct immunoassay. When combining index matching with a silver enhancement step, a detection limit of 0.1 ng mL(-1) human IgG and a 5 log dynamic range was achieved. The demonstrated technique provides a simple method for enhancing optical sensitivity for a wide range of assays, enabling the full benefits of porous detection elements in miniaturized analytical systems to be realized.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26160546      PMCID: PMC4516631          DOI: 10.1039/c5an00988j

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  24 in total

1.  Scanometric DNA array detection with nanoparticle probes.

Authors:  T A Taton; C A Mirkin; R L Letsinger
Journal:  Science       Date:  2000-09-08       Impact factor: 47.728

2.  Simultaneous determination of pesticides using a four-band disposable optical capillary immunosensor.

Authors:  Christos Mastichiadis; Sotirios E Kakabakos; Ion Christofidis; Michael A Koupparis; Caroline Willetts; Konstantinos Misiako
Journal:  Anal Chem       Date:  2002-12-01       Impact factor: 6.986

Review 3.  Commercialization of microfluidic point-of-care diagnostic devices.

Authors:  Curtis D Chin; Vincent Linder; Samuel K Sia
Journal:  Lab Chip       Date:  2012-02-17       Impact factor: 6.799

4.  Novel plastic biochips for colorimetric detection of biomolecules.

Authors:  Jing Wen; Xiaoli Shi; Yining He; Jianjun Zhou; Yunchao Li
Journal:  Anal Bioanal Chem       Date:  2012-08-08       Impact factor: 4.142

5.  Flow-through immunosensors using antibody-immobilized polymer monoliths.

Authors:  Jikun Liu; Chien-Fu Chen; Chih-Wei Chang; Don L DeVoe
Journal:  Biosens Bioelectron       Date:  2010-06-11       Impact factor: 10.618

6.  In situ scanometric assay of cell surface carbohydrate by glyconanoparticle-aggregation-regulated silver enhancement.

Authors:  Lin Ding; Ruocan Qian; Yadong Xue; Wei Cheng; Huangxian Ju
Journal:  Anal Chem       Date:  2010-07-01       Impact factor: 6.986

7.  Microfluidic patterning of miniaturized DNA arrays on plastic substrates.

Authors:  Matthias Geissler; Emmanuel Roy; Gerardo A Diaz-Quijada; Jean-Christophe Galas; Teodor Veres
Journal:  ACS Appl Mater Interfaces       Date:  2009-07       Impact factor: 9.229

Review 8.  Tackling HIV through robust diagnostics in the developing world: current status and future opportunities.

Authors:  Darash Desai; Grace Wu; Muhammad H Zaman
Journal:  Lab Chip       Date:  2010-12-01       Impact factor: 6.799

9.  Microscale patterning of thermoplastic polymer surfaces by selective solvent swelling.

Authors:  Omid Rahmanian; Chien-Fu Chen; Don L DeVoe
Journal:  Langmuir       Date:  2012-08-23       Impact factor: 3.882

Review 10.  Unconventional low-cost fabrication and patterning techniques for point of care diagnostics.

Authors:  Himanshu Sharma; Diep Nguyen; Aaron Chen; Valerie Lew; Michelle Khine
Journal:  Ann Biomed Eng       Date:  2010-12-09       Impact factor: 3.934

View more
  3 in total

1.  Novel functionalities of hybrid paper-polymer centrifugal devices for assay performance enhancement.

Authors:  M S Wiederoder; S Smith; P Madzivhandila; D Mager; K Moodley; D L DeVoe; K J Land
Journal:  Biomicrofluidics       Date:  2017-09-12       Impact factor: 2.800

2.  Flow-through microfluidic immunosensors with refractive index-matched silica monoliths as volumetric optical detection elements.

Authors:  M S Wiederoder; E L Kendall; J-H Han; R G Ulrich; D L DeVoe
Journal:  Sens Actuators B Chem       Date:  2017-07-21       Impact factor: 7.460

3.  Impedimetric Immunosensing in a Porous Volumetric Microfluidic Detector.

Authors:  Michael S Wiederoder; Isaac Misri; Don L DeVoe
Journal:  Sens Actuators B Chem       Date:  2016-05-06       Impact factor: 7.460

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.