Literature DB >> 26159356

Transcatheter Embolisation of Proximal Type 1 Endoleaks Following Endovascular Aneurysm Sealing (EVAS) Using the Nellix Device: Technique and Outcomes.

S Ameli-Renani1, R A Morgan2.   

Abstract

AIM: To evaluate the technical success and mid-term outcomes following transcatheter embolisation of type 1a endoleak after Nellix endovascular aneurysm sealing (EVAS).
MATERIALS AND METHODS: Seven patients (5 men; mean age 83; range 79-90) underwent transcatheter embolisation between July 2013 and August 2014. The average time from EVAS to embolisation was 136 days (range 6-301) and from endoleak diagnosis to embolisation was 20 days (range 2-50). Embolisation was performed with coils and Onyx in six cases and Onyx only in one case. Technical success, imaging and clinical outcomes of embolisation were reviewed. Technical success was defined as elimination of the endoleak on completion angiography and first imaging follow-up. Clinical success was defined as unchanged or decreased aneurysm sac size on subsequent follow-up (average 8 months; range 103-471 days).
RESULTS: All cases were technically successful. One patient required a second endovascular procedure following Onyx reflux into the Nellix endograft and another patient required surgical closure of a brachial puncture site. All patients are endoleak free with stable sac size on the latest available follow-up imaging.
CONCLUSION: If a type 1 endoleak occurs after EVAS, embolisation using Onyx with or without coils is feasible and effective with high technical success and freedom from endoleak recurrence at mid-term follow-up.

Entities:  

Keywords:  Abdominal aortic aneurysm; Aorta; Embolisation; Endovascular aortic aneurysm; Transcatheter arterial embolisation

Mesh:

Substances:

Year:  2015        PMID: 26159356     DOI: 10.1007/s00270-015-1171-7

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  3 in total

1.  Two-Year Outcomes of the Nellix EndoVascular Aneurysm Sealing System for Treatment of Abdominal Aortic Aneurysms.

Authors:  Aleksandra C Zoethout; Johannes T Boersen; Jan M M Heyligers; Jean-Paul P M de Vries; Clark J A M Zeebregts; Michel M P J Reijnen
Journal:  J Endovasc Ther       Date:  2018-03-29       Impact factor: 3.487

2.  A Case of Late Type Ia Endoleak After Endovascular Aneurysm Sealing Using the Nellix System: Proximal Extension with Triple Chimney and Gutter Endoleak Embolization.

Authors:  Pietro Volpe; Antonino Alberti; Vittorio Alberti; Mafalda Massara
Journal:  Ann Vasc Dis       Date:  2021-12-25

Review 3.  Secondary Endoleak Management Following TEVAR and EVAR.

Authors:  Seyed Ameli-Renani; Vyzantios Pavlidis; Robert A Morgan
Journal:  Cardiovasc Intervent Radiol       Date:  2020-08-10       Impact factor: 2.740

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.