Percutaneous Renal Tumor Ablation: Radiation Exposure During Cryoablation and Radiofrequency Ablation.

James C McEachen1, Shuai Leng2, Thomas D Atwell2, Matthew K Tollefson3, Jeremy L Friese2, Zhen Wang4, M Hassan Murad4, Grant D Schmit2.   

Abstract

INTRODUCTION: Once reserved solely for non-surgical cases, percutaneous ablation is becoming an increasingly popular treatment option for a wider array of patients with small renal masses and the radiation risk needs to be better defined as this transition continues.
MATERIALS AND METHODS: Retrospective review of our renal tumor ablation database revealed 425 patients who underwent percutaneous ablation for treatment of 455 renal tumors over a 5-year time period. Imparted radiation dose information was reviewed for each procedure and converted to effective patient dose and skin dose using established techniques. Statistical analysis was performed with each ablative technique.
RESULTS: For the 331 cryoablation procedures, the mean DLP was 6987 mGycm (SD = 2861) resulting in a mean effective dose of 104.7 mSv (SD = 43.5) and the mean CTDIvol was 558 mGy (SD = 439) resulting in a mean skin dose of 563.2 mGy (SD = 344.1). For the 124 RFA procedures, the mean DLP was 3485 mGycm (SD = 1630) resulting in a mean effective dose of 50.3 mSv (SD = 24.0) and the mean CTDIvol was 232 mGy (SD = 149) resulting in a mean skin dose of 233.2 mGy (SD = 117.4). The difference in patient radiation exposure between the two renal ablation techniques was statistically significant (p < 0.001).
CONCLUSION: Both cryoablation and RFA imparted an average skin dose that was well below the 2 Gy deterministic threshold for appreciable sequela. Renal tumor cryoablation resulted in a mean skin and effective radiation dose more than twice that for RFA. The radiation exposure for both renal tumor ablation techniques was at the high end of the medical imaging radiation dose spectrum.

Entities:  

Keywords:  Ablation; CT/CTA; Clinical practice; Interventional oncology; Kidney/renal; Radiation; Radiofrequency ablation

Mesh:

Year:  2015        PMID: 26159355     DOI: 10.1007/s00270-015-1169-1

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  1 in total

1.  Percutaneous CT-Guided Renal Cryoablation: Technical Aspects, Safety, and Long-Term Oncological Outcomes in a Single Center.

Authors:  Stefano Cernic; Cristina Marrocchio; Riccardo Ciabattoni; Ilaria Fiorese; Fulvio Stacul; Fabiola Giudici; Michele Rizzo; Maria Assunta Cova
Journal:  Medicina (Kaunas)       Date:  2021-03-20       Impact factor: 2.430

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.