Does the hybrid light source (LED/laser) influence temperature variation on the enamel surface during 35% hydrogen peroxide bleaching? A randomized clinical trial.

Patricia Moreira de Freitas, Andressa Nery Menezes, Ana Carolina Costa da Mota, Alyne Simões, Fausto Medeiros Mendes, Andrea Dias Neves Lago, Leila Soares Ferreira, Thayanne Monteiro Ramos-Oliveira.   

Abstract

OBJECTIVE: The present study investigated how a hybrid light source (LED/laser) influences temperature variation on the enamel surfaces during 35% hydrogen peroxide (HP) bleaching. Effects on the whitening effectiveness and tooth sensitivity were analyzed. METHOD AND MATERIALS: Twenty-two volunteers were randomly assigned to two different treatments in a split-mouth experimental model: group 1 (control), 35% HP; group 2 (experimental), 35% HP + LED/laser. Color evaluation was performed before treatment, and 7 and 14 days after completion of bleaching, using a color shade scale. Tooth sensitivity was assessed using a visual analog scale (VAS; before, immediately, and 24 hours after bleaching). During the bleaching treatment, thermocouple channels positioned on the tooth surfaces recorded the temperature. Data on color and temperature changes were subjected to statistical analysis (α = 5%). Tooth sensitivity data were evaluated descriptively.
RESULTS: Groups 1 and 2 showed mean temperatures (± standard deviation) of 30.7 ± 1.2 °C and 34.1 ± 1.3 °C, respectively. It was found that there were statistically significant differences between the groups, with group 2 showing higher mean variation (P < .0001). The highest temperature variation occurred for group 2, with an increase of 5.3 °C at the enamel surface. The color change results showed no differences in bleaching between the two treatment groups (P = .177). The variation of the average temperature during the treatments was not statistically associated with color variation (P = .079). Immediately after bleaching, it was found that 36.4% of the subjects in group 2 had mild to moderate sensitivity. In group 1, 45.5% showed moderate sensitivity. In both groups, the sensitivity ceased within 24 hours.
CONCLUSION: Hybrid light source (LED/ laser) influences temperature variation on the enamel surface during 35% HP bleaching and is not related to greater tooth sensitivity.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26159208     DOI: 10.3290/j.qi.a34454

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677