| Literature DB >> 26157252 |
Mizuki Hachiya1, Shin Murata2, Hiroshi Otao3, Kenji Kamijou3, Katsuhiko Mizota3, Toyoko Asami4.
Abstract
[Purpose] This study aimed to investigate the reproducibility and validity of the 50-m walking test. [Subjects] Reproducibility was investigated in 19 community-dwelling elderly women (mean age, 76.3 years), and validity was investigated in 31 community-dwelling elderly individuals (12 men and 19 women; mean age, 75.7 years). [Methods] The time taken to walk 50 m, the time taken to walk each 10-m section (laps 1-5), the time taken to walk 10 m, and grip strength were measured. In addition, the functional reach test (FRT), one-leg standing test, and timed up and go (TUG) test were performed.Entities:
Keywords: 50-meter walk test; Reproducibility; Validity
Year: 2015 PMID: 26157252 PMCID: PMC4483430 DOI: 10.1589/jpts.27.1511
Source DB: PubMed Journal: J Phys Ther Sci ISSN: 0915-5287
Fig. 1. Diagram of the 50-m walking test measurement model
ICCs for the 50-m walking test and laps 1–5 (n=19)
| Gait speed (s) (Mean ± SD) | ICC (95% CI) | Bland-Altman method | LOA | SEM | MDC95 | |||||
|---|---|---|---|---|---|---|---|---|---|---|
| Fixed bias | Proportional bias | |||||||||
| Trial 1 | Trial 2 | ρ | 95% CI | Regression line angle | (s) | (s) | (s) | |||
| 50-m walking test | 38.9 ±6.6 | 38.4 ±6.5 | 0.97 | (0.92–0.99 ) | −0.22–1.31 | 0.02 | p=0.78 | −1.25–2.35 | 1.5 | 3.1 |
| Lap 1 | 6.7 ±1.1 | 6.6 ±1.2 | 0.94 | (0.85–0.98 ) | −0.11–0.28 | −0.08 | p=0.36 | −0.37–0.54 | 0.3 | 0.8 |
| Lap 2 | 7.8 ±1.3 | 7.8 ±1.3 | 0.96 | (0.91–0.99 ) | −0.12–0.24 | 0.03 | p=0.62 | −0.35–0.47 | 0.3 | 0.7 |
| Lap 3 | 8.0 ±1.3 | 7.9 ±1.3 | 0.95 | (0.87–0.98 ) | −0.12–0.30 | −0.01 | p=0.98 | −0.41–0.58 | 0.3 | 0.9 |
| Lap 4 | 8.1 ±1.4 | 8.0 ±1.4 | 0.94 | (0.84–0.98 ) | −0.09–0.38 | −0.04 | p=0.64 | −0.42–0.70 | 0.3 | 1.0 |
| Lap 5 | 8.3 ±1.5 | 8.1 ±1.3 | 0.93 | (0.83–0.97 ) | −0.07–0.42 | 0.11 | p=0.22 | −0.39–0.75 | 0.3 | 1.0 |
ICC: intraclass correlation coefficient; CI: confidence interval; LOA: limits of agreement; SEM: standard error measurement; MDC: minimal detectable change; SD: standard deviation
Measured values (n=31)
| Mean | SD | ||
|---|---|---|---|
| 50-m walking test | (s) | 37.6 | 6.6 |
| Lap 1 | (s) | 6.4 | 1.1 |
| Lap 2 | (s) | 7.6 | 1.4 |
| Lap 3 | (s) | 7.8 | 1.4 |
| Lap 4 | (s) | 7.8 | 1.4 |
| Lap 5 | (s) | 8.0 | 1.5 |
| 10-m walking test | (s) | 6.5 | 1.3 |
| Grip strength | (kg) | 27.0 | 8.4 |
| FRT | (cm) | 28.3 | 6.1 |
| One-leg standing test | (s) | 32.0 | 38.8 |
| TUG | (s) | 6.7 | 1.4 |
FRT: functional reach test; TUG: timed up & go test; SD: standard deviation
Correlation analysis between the measurement items
| Male (n=12) | Female (n=19) | |||||||
|---|---|---|---|---|---|---|---|---|
| 50-m walking test | 10-m walking test | 50-m walking test | 10-m walking test | |||||
| 10-m walking test | 0.87 | ** | 0.83 | ** | ||||
| Grip strength | −0.39 | −0.54 | −0.60 | ** | −0.50 | * | ||
| FRT | −0.79 | ** | −0.81 | ** | −0.60 | ** | −0.58 | ** |
| One-leg standing test | −0.43 | 0.01 | −0.50 | * | −0.59 | * | ||
| TUG | 0.82 | ** | 0.87 | ** | 0.96 | ** | 0.81 | ** |
| Pearson correlation coefficient: *p<0.05; **p<0.01. FRT: functional reach test; TUG: timed up and go test | ||||||||
| Male (n=12) | Female (n=19) | |||||||
| 50-m walking test | 10-m walking test | 50-m walking test | 10-m walking test | |||||
| 10-m walking test | 0.74 | * | 0.69 | ** | ||||
| Grip strength | −0.01 | −0.15 | −0.47 | −0.32 | ||||
| FRT | −0.60 | −0.65 | * | −0.20 | −0.28 | |||
| One-leg standing test | −0.10 | 0.26 | −0.06 | −0.34 | ||||
| TUG | 0.84 | ** | 0.78 | ** | 0.92 | ** | 0.66 | ** |
Partial correlation coefficient (controlling for age): *p<0.05; **p<0.01.