Reproducibility and validity of the 50-meter walking test in community-dwelling elderly.

Mizuki Hachiya1, Shin Murata2, Hiroshi Otao3, Kenji Kamijou3, Katsuhiko Mizota3, Toyoko Asami4.   

Abstract

[Purpose] This study aimed to investigate the reproducibility and validity of the 50-m walking test. [Subjects] Reproducibility was investigated in 19 community-dwelling elderly women (mean age, 76.3 years), and validity was investigated in 31 community-dwelling elderly individuals (12 men and 19 women; mean age, 75.7 years). [Methods] The time taken to walk 50 m, the time taken to walk each 10-m section (laps 1-5), the time taken to walk 10 m, and grip strength were measured. In addition, the functional reach test (FRT), one-leg standing test, and timed up and go (TUG) test were performed.
[Results] In a reproducibility analysis, the interclass correlation coefficient (1,1) was 0.97. In a Bland-Altman analysis, no systematic error was found. The measured values from the 50-m walking test included a measurement error of 1.5 s, and the acceptable margin of error was confirmed to be 3.1 s. In a validity analysis, the 50-m walking test score was significantly correlated with the 10-m walking and TUG test scores.
[Conclusion] Our results suggest that the 50-m walking test score may be a useful index of the walking ability of community-dwelling elderly.

Entities:  

Keywords:  50-meter walk test; Reproducibility; Validity

Year:  2015        PMID: 26157252      PMCID: PMC4483430          DOI: 10.1589/jpts.27.1511

Source DB:  PubMed          Journal:  J Phys Ther Sci        ISSN: 0915-5287


INTRODUCTION

Many studies on walking have been performed. Walking ability can be assessed by having a subject walk a specified distance in a straight line, and recording the time required and walking speed. Previous studies have shown that walking ability is associated with factors such as activities of daily living and balance1, 2), and that walking speed measurements are highly reproducible3). Walking speed slows with advancing age4) and is known to contribute to the survival of elderly people5). Measurement of walking speed is a highly versatile assessment method because reference values are available for different age groups4) and it is simple and easy to execute. Studies have suggested, however, that 10-m walking time may not be a good measure of the endurance or balance of healthy elderly people6). The relationship between walking speed and leg muscle strength is also nonlinear7). If leg muscle strength decreases at the same rate as walking speed, an association will be evident between them. In people with normal walking ability, however, walking speed does not reflect an improvement in leg muscle strength. This suggests that although short-distance walking tests over 5 or 10 m may be useful for assessing the walking ability of people with disorders or the frail elderly, they may not provide an appropriate assessment of physical function in healthy elderly people. Hachiya et al.6) developed the 50-m walking test to assess walking ability in the elderly and investigated the feasibility of its use for elderly people in local gatherings for testing physical fitness (tairyoku sokutei kai). They confirmed that the 50-m walking test was highly associated with quadriceps muscle strength, and the 30-second chair stand (CS-30), one-leg standing, and timed up and go (TUG) test scores. In addition, 5-m walking time has been confirmed to be associated with quadriceps muscle strength and TUG test score, but not with CS-30 and one-leg standing test scores. The reproducibility of the 50-m walking test, however, has yet to be established. If the types of error in the measurements and their acceptable margins were to be ascertained, this method might offer a valuable assessment tool. This study aimed to describe the measurement method used in the 50-m walking test and to investigate its criterion-related validity.

SUBJECTS AND METHODS

The study subjects were community-dwelling elderly people who were voluntary participants in a dementia-prevention project. The subjects of the reproducibility analysis for the 50-m walking test were 19 women (age, 76.3 ± 5.7 years; height, 148.8 ± 6.3 cm; weight, 49.6 ± 8.6 kg; all the data are presented as mean ± standard deviation values). The subjects of the validity analysis for the 50-m walking test were 31 individuals (12 men and 19 women; age, 75.7 ± 6.0 years; height, 153.6 ± 9.1 cm; weight, 53.8 ± 9.9 kg). Individuals with neurological or joint disorders who required treatment were excluded. The subjects were independent to the extent that they were able to participate in the study by themselves, arriving in their own vehicles or by passenger bus. In terms of ethical considerations, informed consent was obtained from the subjects before measurements were started. This study was approved by the Study Group for Promoting Healthy Longevity in Imari, Japan. In addition to the 50-m walking test, walking ability was also assessed in terms of the 10-m walking test. Physical function was assessed by means of grip strength, the functional reach test (FRT), one-leg standing test, and timed up and go (TUG) test. The 50-m walking test was performed by having the subjects walk 2.5 return journeys between two cones placed 10 m apart along a walking course, for a total of 50 m (Fig. 1). The time taken to complete 50 m was measured by using a stopwatch. The items required were markers (cones) indicating where to change direction and a stopwatch with a lap time function. Before the start of measurement, the subjects stood still beside a cone. They were instructed to walk to the other when signaled by the investigator, go around it to the outer side, and walk back again as fast as possible. They were asked to walk 2.5 complete circuits of the 10-m course, without a break. The stopwatch was used to measure interval times from the start of walking to 40 m (second return journey), with the stop button pressed at the end of 50 m. The evaluation items recorded were the time required to walk 50 m and the times required to walk each of laps 1–5 (all times in seconds). Measurements were performed twice. One lap was defined as the interval distance from one cone to the other cone, which was 10 m away.
Fig. 1.

Diagram of the 50-m walking test measurement model

Diagram of the 50-m walking test measurement model The 10-m walking test was measured with a stopwatch as the time required to walk 10 m on a flat surface at the maximum walking speed. Measurements were performed twice, and the shortest time (in seconds) was used as the representative time. Grip strength was measured by using a digital handgrip dynamometer (T.K.K. 5401, Takei Scientific Instruments Co., Ltd., Niigata, Japan). Measurements were performed twice each for the right and left hands, with the subject standing, and the left and right arms hanging down alongside the body. The greatest value was used as the representative value. The FRT8) was performed by using a functional reach measuring device (T.K.K. 5802, Takei Scientific Instruments Co., Ltd., Niigata, Japan). The subjects were asked to stand with their feet at around shoulder width apart and maintain an arm position with the forearm pronated, the elbow extended, and the shoulder flexed at 90° when measurements were started. They were then asked to reach as far as possible in front of them. Measurements were performed twice, and the maximum distance (in centimeters) was used as the representative value. The one-leg standing test was performed by asking the subjects to lift one leg in their own time and by using a stopwatch to measure the time for which they could maintain this position. The measurement was concluded either when the supporting leg moved from its position at the start of measurement or the raised leg touched the floor. Measurements were performed twice each for the right and left legs, and the longest time (in seconds) was used as the representative value. The TUG test2) was performed by using a stopwatch to measure the time taken by the subjects to rise from a sitting position on an armless chair with its seat 40 cm off the ground, walk around a pole 3 m in front of the chair, and return to the seated position after being given a signal to start. They were asked to walk as fast as possible. Measurements were performed twice, and the fastest time (in seconds) was used as the representative time. In terms of statistical analysis, the relative reproducibility of the 50-m walking test and laps 1–5 was investigated by calculating the intraclass correlation coefficient (ICC) to test the reproducibility of the measurements made by the same investigator. Absolute reliability9, 10) was tested by means of a Bland-Altman analysis. After the systematic error was determined, measurement error was investigated by calculating the standard error of measurement (SEM) up to the 95% confidence interval for the minimal detectable change (MDC95) as the acceptable rate of error. For the validity of the 50-m walking test, the association with each of the measurement values was investigated in light of the Pearson correlation coefficient for each gender. Next, the partial correlation coefficient was investigated by using age as a control factor for each gender. SPSS Statistics 22 (IBM Corp., Armonk, NY, USA) was used for the ICC calculation and correlation analysis, and R 2.8.1 was used for the Bland-Altman analysis, SEM, and MDC95 calculations. The level of significance was set at p < 0.05.

RESULTS

Table 1 shows the results of the 50-m walking test and laps 1–5 for the 19 subjects. The ICC (1,1) for the 50-m walking test was 0.97. In the Bland-Altman analysis, we found no systematic error. The SEM was 1.5 s, and the MDC95 was 3.1 s (Table 1).
Table 1.

ICCs for the 50-m walking test and laps 1–5 (n=19)

Gait speed (s) (Mean ± SD)ICC (95% CI)Bland-Altman methodLOASEMMDC95

Fixed biasProportional bias







Trial 1Trial 2ρ95% CIRegression line angle(s)(s)(s)
50-m walking test38.9 ±6.6 38.4 ±6.5 0.97 (0.92–0.99 )−0.22–1.310.02p=0.78−1.25–2.351.5 3.1
Lap 16.7 ±1.1 6.6 ±1.2 0.94 (0.85–0.98 )−0.11–0.28−0.08p=0.36−0.37–0.540.3 0.8
Lap 27.8 ±1.3 7.8 ±1.3 0.96 (0.91–0.99 )−0.12–0.240.03p=0.62−0.35–0.470.3 0.7
Lap 38.0 ±1.3 7.9 ±1.3 0.95 (0.87–0.98 )−0.12–0.30−0.01p=0.98−0.41–0.580.3 0.9
Lap 48.1 ±1.4 8.0 ±1.4 0.94 (0.84–0.98 )−0.09–0.38−0.04p=0.64−0.42–0.700.3 1.0
Lap 58.3 ±1.5 8.1 ±1.3 0.93 (0.83–0.97 )−0.07–0.420.11p=0.22−0.39–0.750.3 1.0

ICC: intraclass correlation coefficient; CI: confidence interval; LOA: limits of agreement; SEM: standard error measurement; MDC: minimal detectable change; SD: standard deviation

ICC: intraclass correlation coefficient; CI: confidence interval; LOA: limits of agreement; SEM: standard error measurement; MDC: minimal detectable change; SD: standard deviation Table 2 shows the means and standard deviations of each measurement in the 50-m walking test and laps 1–5. In the correlation analysis, the 50-m walking test showed a significant correlation with the 10-m walking time (r = 0.89), FRT score (r = −0.79), and TUG test score (r = 0.81) in the men. The 10-m walking time showed a significant correlation with FRT (r = −0.81) and TUG test scores (r = 0.82). In the women, the 50-m walking test score showed a significant correlation with the 10-m walking time (r = 0.83), grip strength (r = −0.60), FRT score (r = −0.60), one-leg standing test score (r = −0.50), and TUG test score (r = 0.96). The 10-m walking time showed a significant correlation with grip strength (r = −0.50), FRT score (r = −0.58), one-leg standing test score (r = −0.59), and TUG test score (r = 0.81). In the partial correlation analysis controlled by age, the 50-m walking test score showed a significant correlation with the 10-m walking time (r = 0.74) and TUG test score (r = 0.84) in the men. The 10-m walking time showed a significant correlation with FRT (r = −0.65) and TUG test scores (r = 0.78). In the women, the 50-m walking test score showed a significant correlation with the 10-m walking time (r = 0.69) and TUG test score (r = 0.92). The 10-m walking time showed a significant correlation with TUG test score (r = 0.66; Table 3).
Table 2.

Measured values (n=31)

MeanSD
50-m walking test(s)37.6 6.6
Lap 1(s)6.4 1.1
Lap 2(s)7.6 1.4
Lap 3(s)7.8 1.4
Lap 4(s)7.8 1.4
Lap 5(s)8.0 1.5
10-m walking test(s)6.5 1.3
Grip strength(kg)27.0 8.4
FRT(cm)28.3 6.1
One-leg standing test(s)32.0 38.8
TUG(s)6.7 1.4

FRT: functional reach test; TUG: timed up & go test; SD: standard deviation

Table 3.

Correlation analysis between the measurement items

Male (n=12)Female (n=19)


50-m walking test10-m walking test50-m walking test10-m walking test
10-m walking test0.87 **0.83 **
Grip strength−0.39 −0.54 −0.60 **−0.50 *
FRT−0.79 **−0.81 **−0.60 **−0.58 **
One-leg standing test−0.43 0.01 −0.50 *−0.59 *
TUG0.82 **0.87 **0.96 **0.81 **

Pearson correlation coefficient: *p<0.05; **p<0.01. FRT: functional reach test; TUG: timed up and go test

Male (n=12)Female (n=19)


50-m walking test10-m walking test50-m walking test10-m walking test

10-m walking test0.74 *0.69 **
Grip strength−0.01 −0.15 −0.47 −0.32
FRT−0.60 −0.65 *−0.20 −0.28
One-leg standing test−0.10 0.26 −0.06 −0.34
TUG0.84 **0.78 **0.92 **0.66 **

Partial correlation coefficient (controlling for age): *p<0.05; **p<0.01.

FRT: functional reach test; TUG: timed up & go test; SD: standard deviation Partial correlation coefficient (controlling for age): *p<0.05; **p<0.01.

DISCUSSION

In this study, we investigated the reproducibility and validity of the 50-m walking test for community-dwelling elderly persons. We found that the 50-m walking test was highly reliable and exhibited results significantly correlated with the 10-m walking and TUG test scores. Our findings confirmed that the 50-m walking test is a valid assessment method for walking ability. The ICC value for the 50-m walking test was high at 0.97. The ICC values for laps 1–5, the component elements of the 50-m walking test, were also high at 0.93–0.96. The Bland-Altman analysis, which was performed to test for systematic error found no systematic error, in either the 50-m walking test or laps 1–5, confirming that measurement error had no consistent tendency to occur in the measurements in this study. Calculations of the SEM and MDC95 to test for random errors in the measurements resulted in an a SEM of 1.5 s for the 50-m walking test and 3.1 s for the MDC95. This showed that the measurements in the 50-m walking test included a measurement error of 1.5 s and that the acceptable margin of error was 3.1 s. This means that a measurement variation within 3.1 s is within the margin of error, whereas an evident change greater than 3.1 s is caused by a factor other than measurement error. Similarly, the SEM for laps 1–5 was 0.3 s, and the MDC95 was 0.7–1.0 s. In all the cases, the small size of the measurement error means that it can be judged not to pose a problem in clinical use. To evaluate the validity of the 50-m walking test as an assessment method for the walking ability of the elderly subjects, we analyzed the correlation of the 50-m walking test scores with the 10-m walking test scores. We found that the 50-m walking time was significantly correlated with the 10-m walking test score. Regarding the relationships of walking ability assessment with the 50-m walking test and 10-m walking time with the respective physical functions, significant correlations with FRT and TUG test scores were observed for both the 50-m walking test score and 10-m walking time in the men. A significant correlation was not observed between grip strength and one-leg standing test score. In the women, both the 50-m walking test score and 10-m walking time showed a significant correlation with grip strength, FRT score, one-leg standing test score, and TUG test score. The partial correlation analysis with age as a control factor maintained the significant correlative relationship between the TUG test score and both the 50-m walking test score and 10-m walking time for both the men and women. In a previous study6) that evaluated healthy elderly men, a significant correlation was observed between the 50-m walking test score and physical function, thus suggesting that the 50-m walking test is also reflective of balancing ability, which is dissimilar to the results of the present study. One conceivable reason for this is that in the prior study, the impact of age was not taken into account. In light of these facts, the 50-m walking test score was confirmed to be a valid method of assessment, making it possible to ascertain walking ability in the elderly. Our findings confirm the reproducibility of the 50-m walking test, with a maximum measurement error of only approximately 3 s. We also confirmed that the test is useful as an assessment method for walking ability of community-dwelling elderly persons. Furthermore, in light of the results of the present study, the 50-m walking test is possibly affected by aging. Therefore, a greater number of subjects should be included in future studies, and age-specific reference values among elderly persons should be investigated. In addition, as the subjects for the investigation of reliability were only women, the results of the present study might not be applicable to men. Therefore, whether or not the results of the present study can be applied to men needs to be examined.
  6 in total

1.  Functional reach: a new clinical measure of balance.

Authors:  P W Duncan; D K Weiner; J Chandler; S Studenski
Journal:  J Gerontol       Date:  1990-11

2.  Evidence for a non-linear relationship between leg strength and gait speed.

Authors:  D M Buchner; E B Larson; E H Wagner; T D Koepsell; B J de Lateur
Journal:  Age Ageing       Date:  1996-09       Impact factor: 10.668

3.  Age- and gender-related test performance in community-dwelling elderly people: Six-Minute Walk Test, Berg Balance Scale, Timed Up & Go Test, and gait speeds.

Authors:  Teresa M Steffen; Timothy A Hacker; Louise Mollinger
Journal:  Phys Ther       Date:  2002-02

4.  Improvement in usual gait speed predicts better survival in older adults.

Authors:  Susan E Hardy; Subashan Perera; Yazan F Roumani; Julie M Chandler; Stephanie A Studenski
Journal:  J Am Geriatr Soc       Date:  2007-10-03       Impact factor: 5.562

5.  The timed "Up & Go": a test of basic functional mobility for frail elderly persons.

Authors:  D Podsiadlo; S Richardson
Journal:  J Am Geriatr Soc       Date:  1991-02       Impact factor: 5.562

6.  Gait speed and activities of daily living function in geriatric patients.

Authors:  J M Potter; A L Evans; G Duncan
Journal:  Arch Phys Med Rehabil       Date:  1995-11       Impact factor: 3.966

  6 in total
  7 in total

1.  Usefulness of a 50-meter round walking test for fall prediction in the elderly requiring long-term care.

Authors:  Mizuki Hachiya; Shin Murata; Hiroshi Otao; Takehiko Ihara; Katsuhiko Mizota; Toyoko Asami
Journal:  J Phys Ther Sci       Date:  2015-12-28

2.  Association between occlusal force and physical functions in preschool children: a comparison of males and females.

Authors:  Aya Hirao; Shin Murata; Atsuko Kubo; Mizuki Hachiya; Nozomi Mitsumaru; Toyoko Asami
Journal:  J Phys Ther Sci       Date:  2015-12-28

3.  Comparisons of predictive values of sarcopenia with different muscle mass indices in Korean rural older adults: a longitudinal analysis of the Aging Study of PyeongChang Rural Area.

Authors:  Il-Young Jang; Hee-Won Jung; Chang Ki Lee; Sang Soo Yu; Young Soo Lee; Eunju Lee
Journal:  Clin Interv Aging       Date:  2018-01-12       Impact factor: 4.458

4.  Effect of Insoles with a Toe-Grip Bar on Toe Function and Standing Balance in Healthy Young Women: A Randomized Controlled Trial.

Authors:  Hideki Nakano; Shin Murata; Teppei Abiko; Masashi Sakamoto; Dai Matsuo; Michio Kawaguchi; Youji Sugo; Hiroaki Matsui
Journal:  Rehabil Res Pract       Date:  2017-11-14

5.  Activities-specific balance confidence scale for predicting future falls in Indian older adults.

Authors:  Jamal Ali Moiz; Vishal Bansal; Majumi M Noohu; Shailendra Nath Gaur; Mohammad Ejaz Hussain; Shahnawaz Anwer; Ahmad Alghadir
Journal:  Clin Interv Aging       Date:  2017-04-10       Impact factor: 4.458

6.  Sarcopenia is associated with severe erectile dysfunction in older adults: a population-based cohort study.

Authors:  Hyungchul Park; Il-Young Jang; Minkyu Han; Heayon Lee; Hee-Won Jung; Eunju Lee; Dae Hyun Kim
Journal:  Korean J Intern Med       Date:  2020-04-21       Impact factor: 3.165

7.  Using an Accelerometer-Based Step Counter in Post-Stroke Patients: Validation of a Low-Cost Tool.

Authors:  Francesco Negrini; Giulio Gasperini; Eleonora Guanziroli; Jacopo Antonino Vitale; Giuseppe Banfi; Franco Molteni
Journal:  Int J Environ Res Public Health       Date:  2020-05-02       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.