Literature DB >> 26156945

Geometric ring annuloplasty as an adjunct to aortic valve repair: clinical investigation of the HAART 300 device.

Domenico Mazzitelli1, Theodor Fischlein2, J Scott Rankin3, Yeong-Hoon Choi4, Christof Stamm5, Steffen Pfeiffer2, Jan Pirk6, Christian Detter7, Johannes Kroll8, Friedhelm Beyersdorf8, Charles D Griffin9, Malakh Shrestha10, Christian Nöbauer1, Philip S Crooke11, Christian Schreiber1, Rüdiger Lange1.   

Abstract

OBJECTIVES: This study assessed the safety and efficacy of an internal geometric annuloplasty ring in a regulatory trial of aortic valve reconstruction (ClinicalTrials.gov Identifier: NCT01400841).
METHODS: Sixty-five patients with predominant moderate-to-severe trileaflet aortic insufficiency (AI) underwent aortic valve repair with an average age of 63 ± 13 years (mean ± SD). All had initial implantation of an internal aortic annuloplasty ring to correct annular dilatation and facilitate leaflet reconstruction. Leaflet plication was performed for prolapse in 80% of patients, and more complex leaflet procedures, usually employing autologous pericardium, were required in 22%. Ascending aortic and/or root aneurysms were replaced in 62%.
RESULTS: Follow-up was for a maximum of 3 years and a mean of 2 years. No in-hospital operative mortalities, major complications or early or late valve-related events occurred. The annular diameter before repair was 26.5 ± 2.3 mm, and the average ring diameter used was 21.5 ± 1.6 mm. The preoperative AI grade (0-4) was 2.9 ± 0.8 and improved after repair to 0.6 ± 0.7 (P < 0.0001), as did the NYHA class. The mean valve gradient was 8.6 ± 4.3 mmHg, and at 3 years, the Kaplan-Meier survival rate was 95%, with no valve-related mortality. Over the 3 years, aortic valve replacement was required in 7 patients (10.8%) for reasons usually related to surgical technique. Most repair failures occurred early, and results stabilized after 6 months. No structural complications of the rings were observed.
CONCLUSIONS: Geometric ring annuloplasty was a safe and effective adjunct to aortic valve repair. Initial correction of annular dilatation seemed to facilitate overall reconstruction. Because most early repair failures were technical, increasing experience with geometric ring annuloplasty for aortic valve reconstruction has the potential to standardize and improve outcomes.
© The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Entities:  

Keywords:  Aortic annuloplasty; Aortic insufficiency; Aortic valve repair

Mesh:

Year:  2015        PMID: 26156945     DOI: 10.1093/ejcts/ezv234

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  8 in total

1.  Aortic valve repair with a newly approved geometric annuloplasty ring in patients undergoing proximal aortic repair: early results from a single-centre experience.

Authors:  Oliver K Jawitz; Vignesh Raman; Jatin Anand; Muath Bishawi; Soraya L Voigt; Julie Doberne; Andrew M Vekstein; E Hope Weissler; Joseph W Turek; G Chad Hughes
Journal:  Eur J Cardiothorac Surg       Date:  2020-06-01       Impact factor: 4.191

2.  Aortic valve repair for isolated right coronary leaflet prolapse.

Authors:  Arnar Geirsson; Clarence H Owen; Robert S Binford; Rochus K Voeller; Christopher R Burke; Jeffrey D McNeil; Lawrence M Wei; Vinay Badhwar; J Scott Rankin
Journal:  JTCVS Tech       Date:  2022-03-03

3.  Comparison of outcomes following isolated repair of tricuspid versus bicuspid aortic valves.

Authors:  Anatol Prinzing; Johannes Boehm; Magdalena Erlebach; Konstantinos Sideris; Ruediger Lange; Markus Krane
Journal:  J Thorac Dis       Date:  2020-07       Impact factor: 2.895

4.  First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.

Authors:  Jacek H Juściński; Andrzej Koprowski; Magdalena Kołaczkowska; Maciej M Kowalik; Jan A Rogowski; James S Rankin
Journal:  Kardiochir Torakochirurgia Pol       Date:  2018-03-28

5.  Early results of geometric ring annuloplasty for bicuspid aortic valve repair during aortic aneurysm surgery.

Authors:  Marc W Gerdisch; T Brett Reece; Dominic Emerson; Richard S Downey; Geoffrey B Blossom; Arun Singhal; Joshua N Baker; Theodor J M Fischlein; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2022-06-09

Review 6.  Concomitant aortic valve repair for aortic insufficiency and implantation of left ventricle mechanical support.

Authors:  Arun K Singhal; Jarrod Bang; Anthony L Panos; Andrew Feider; Satoshi Hanada; J Scott Rankin
Journal:  J Card Surg       Date:  2022-04-26       Impact factor: 1.778

7.  Commentary: Be ready to re-route your root replacement.

Authors:  John Bozinovski
Journal:  JTCVS Tech       Date:  2021-02-26

8.  Aortic annuloplasty: Subcommissural, intra-annular suture techniques, external and internal rings.

Authors:  Jan M Federspiel; Tristan Ehrlich; Karen Abeln; Hans-Joachim Schäfers
Journal:  JTCVS Tech       Date:  2021-01-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.